background image

5

E

n

g

lis

h

6

E

n

g

lis

h

CONTROLS  AND FUNCTIONS

 (picture ref. pag.21)

1)

" BALANCED INPUT 1” AND " BALANCED INPUT 2”INPUT CONNECTORS

Balanced inputs at line level. Accept “XLR” sockets. 

2)

"OUT 1 ” AND "OUT 2 ” OUTPUT CONNECTORS

The “XLR” connectors be used to send the input audio signal to another amplified 
speaker.
The signal is choosing between “LINK/XOVER” (10) switch.

3)

“LIM” LIMITER   INDICATOR LIGHT

This indicator shows red to indicate that the internal limiter starts working. 
This prevents amplifier distortion and protects the speakers against overloads.

4)

“SGN” SIGNAL INDICATOR LIGHT

This indicator shows green to indicate the presence of the audio signal (at a level of -
20dB). 

5)

“MUTE” INDICATOR LIGHT

This yellow indicator indicates amplifier status. 
The LED is off in normal operating conditions.

6)

“ON” READY INDICATOR LIGHT

This indicator shows green to indicate that the main power voltage is correct.
The LED shows   green normal operating conditions

7)

“SUBWOOFER LEVEL” INPUT SENSITIVITY CONTROL

This control adjusts   the sensitivity of the signal amplifier input. 
This control does not affect the 

"OUT 1 ” and "OUT 2 ” outputs   levels

8)

“PHASE” SWITCH

This two-position switch permits turning the audio signal’s phase   by 180°.
Rotation makes it easier to optimise the reproduction of the low frequencies even in 
the most difficult installation situations. After completing installation, play a piece of 
music and move the switch to achieve the best sound reproduction at low 
frequencies.

9)

“XOVER” SWITCH

T h i s   s w i t c h   p e r m i ts   s e l e c t i n g   t h e   c r o s s o v e r   f r e q u e n c y   b e t w e e n   t h e  
subwoofer and the speakers connected to the "OUT 1 ” and "OUT 2 ” outputs. 
Choice depends on  the type of speaker used for reproduction of mid-high 
frequencies.
For speakers with 12” cones, it is best to use 120Hz, while with 15” 
speakers  90Hz.   

   10)

"LINK/XOVER" SWITCH

This   switch allows to select the signal type to send   "OUT 1 ” and "OUT 2 ” outputs. 
The “LINK” position allows to link the same input signal.
The “XOVER” position allows to send input signal according to crossover frequency 
select by XOVER (9) switch.

11)

"MAINS INPUT" POWER SOCKET

For connecting the power cable provided.
The connector used for mains connection is a POWER CON® (blue) socket.

12)

“MAINS LINK” POWER SOCKETS

For linking the mains power. The outputs are connected in parallel with input (11) and 
can be used   to power other   active speakers. 
The connectors are   POWER CON® (grey) sockets.

13)

"MAINS FUSE"   FUSE CARRIER

Mains fuse housing.

14)

COOLING GRILLE

These grilles permit cooling the amplifier during operation. 
Do not block accesses and clean the grilles whenever necessary to ensure correct 
air circulation.

TECHNICAL SPECIFICATIONS

  

   System

Active

®

Type of   amplifier

Class  D   (DIGIPRO ) 

RMS power

1000W

Music power

2000W

Frequency response

 40-120Hz 

(-3dB)

38Hz - XOVER (-10dB)

Crossover

90Hz - 120Hz selectable   24dB/oct

Sound pressure (max SPL)

135dB

Woofer

1x15” neodymium   -     4” voice coil

 

Input sensitivity

max -3dBu

Impedance input

 

Balanced

 20Kohm

Unbalanced

 10Kohm

Power supply

 

Full-range with PFC, 100-240Vac,       50-60Hz

Housing shape

 Rectangular

Colour

Black

Dimension (WxHxD)

515x440x720mm

Weight

37,5Kg

Weight (with brackets)

41,5 Kg

Pole mount cup

M20 (aluminium)

Handle

4 metal (2   per side)

CHARACTERISTICS 

Cooling

The amplifier is cooled by means of the aluminium panel placed on the back of the speaker.

The thermal protection is ensured by an internal circuit which controls the temperature of 
the amplifier and protects this against any risk of overheating thus limiting in proportion   the 
general volume ( temperature >70°C).

If the temperature reaches the maximum operating temperature (>80°C), the audio signal 
is set to the “MUTE” position and it will be indicated by the switching on of the yellow 
“MUTE” LED.

The requiriered volume and all functions will be restored automatically when the normal 
operating temperatures are reached.

Protections

When the yellow “MUTE” LED turns on, it means that a malfunction has been detected on 
the speaker, thus setting this to the mute position.

Perform   the checks listed below:

Check if the speaker   is properly connected to the power supply.

-

 Make sure   that the power supply is of correct voltage.

Check that the amplifier is not overheated.

Disconnect the speaker from the mains power supply, wait for a few minutes and 

connect it   again. 

If after these tests the yellow “MUTE” LED is still on, please contact an authorised service 
centre.

EMI CLASSIFICATION

According to the standards EN 55103 this equipment is designed and suitable to operate in E4 
Electromagnetic environment. 

Summary of Contents for Digipro S09dp

Page 1: ...MANUALE D USO USER MANUAL BEDIENUNGSANLEITUNG CARACTERISTIQUES TECHNIQUES Made in Italy COD 420120162A Rev 4 0 digital power R R S S0 0 STEREO ACTIVE SUBWOOFER ...

Page 2: ...g BAND PASS so that high sound pressures can be achieved in compact dimensions For easy use installation and transport are provided with handles on sides DVAS09dp White excluded standard M20 pole mount plate DVAS09dp White excluded top part of the box features recesses for making it easier to superimpose another subwoofer rigging predisposition wheels predisposition DVAS09dp White excluded CONNECT...

Page 3: ... s phase by 180 Rotation makes it easier to optimise the reproduction of the low frequencies even in the most difficult installation situations After completing installation play a piece of music and move the switch to achieve the best sound reproduction at low frequencies 9 XOVER SWITCH This switch permits selecting the crossover frequency between the subwoofer and the speakers connected to the O...

Page 4: ... risk of overheating thus limiting in proportion the general volume temperature 70 C If the temperature reaches the maximum operating temperature 80 C the audio signal is set to the MUTE position and it will be indicated by the switching on of the yellow MUTE LED The requiriered volume and all functions will be restored automatically when the normal operating temperatures are reached Protections W...

Page 5: ...EVEL LINK XOVER 0dB Stereo SERIAL N SERIAL N CAUTION TO PREVENT ELECTRICAL SHOCK DO NOT REMOVE COVER AVIS RISQUE DE CHOCH ELECTRIQUE NE PAS OUVRIR Made in Italy ON F F O ON F F O ON F F O B d TECHNOLOGIES TECHNOLOGIES digital power digital power digital power digital power INPUT 1 MONO BALANCED INPUTS BALANCED OUTPUTS INPUT 2 1 2 3 1 GND 2 HOT 3 COLD 1 2 3 S0 PUSH PUSH PUSH PUSH STEREO ACTIVE SUBW...

Page 6: ...LANCED CH2 INPUT LINK L N FULL RANGE MAINS INPUT Switching Mode Power Supply SMPS MAINS FUSE MAINS LINK XOVER FREQ uPROCESSOR XOVER Class D DIGIPRO XOVER LIMITER U VOL ME BALANCED CH1 INPUT LINK XOVER FREQ XOVER XOVER BALANCED CH1 OUT BALANCED CH2 OUT H E P AS Class D L N LIMITER SIGNAL MUTE READY MAINS LINK L N ...

Page 7: ...PUSH PUSH BALANCED INPUT BALANCED LINK OUT 1 GND 2 HOT 3 COLD PUSH BALANCED INPUT BALANCED LINK OUT 1 GND 2 HOT 3 COLD PUSH Digital Vertical Array T 4 BALANCED INPUT BALANCED LINK OUT 1 GND 2 HOT 3 COLD PUSH Digital Vertical Array T 4 BALANCED INPUT BALANCED LINK OUT 1 GND 2 HOT 3 COLD PUSH MIXER S S0 0 LINK XOVER LINK XOVER CONFIGURAZIONI e CONFIGURATION and KONFIGURATIONEN und CONFIGURATIONS et ...

Page 8: ...ION and KONFIGURATIONEN und CONFIGURATIONS et COLLEGAMENTI CABLE CONNECTIONS VERKABELUNG CABLAGE LINK XOVER ON MUTE SGN LIM PHASE 90Hz 8 0dB Mono OUT 1 OUT 2 120Hz 0 180 XOVER SUB WOOFER LEVEL LINK XOVER 0dB Stereo INPUT 1 MONO BALANCED INPUTS BALANCED OUTPUTS INPUT 2 1 1 2 2 3 3 1 GND 2 HOT 3 COLD 1 2 3 PUSH PUSH PUSH PUSH ON MUTE SGN LIM PHASE 90Hz 8 0dB Mono OUT 1 OUT 2 120Hz 0 180 XOVER SUB WO...

Page 9: ... MONO BALANCED INPUTS BALANCED OUTPUTS INPUT 2 1 1 2 2 3 3 1 GND 2 HOT 3 COLD 1 2 3 PUSH PUSH PUSH PUSH ACTIVE SPEAKER MIXER LINK XOVER ACTIVE SUBWOOFER MIXER LINK XOVER READY MUTE SIGNAL LIMITER SENSITIVITY 0dB 8 4dB MODE 3dB BALANCED INPUT LINK OUT PUSH FLAT STAGE MONITOR ON MUTE SGN LIM PHASE 90Hz 8 0dB Mono OUT 1 OUT 2 120Hz 0 180 XOVER SUB WOOFER LEVEL LINK XOVER 0dB Stereo INPUT 1 MONO BALAN...

Page 10: ...reo INPUT 1 MONO BALANCED INPUTS BALANCED OUTPUTS INPUT 2 1 1 2 2 3 3 1 GND 2 HOT 3 COLD 1 2 3 PUSH PUSH PUSH PUSH ACTIVE SUBWOOFER ACTIVE SUBWOOFER ON MUTE SGN LIM PHASE 90Hz 8 0dB Mono OUT 1 OUT 2 120Hz 0 180 XOVER SUB WOOFER LEVEL LINK XOVER 0dB Stereo INPUT 1 MONO BALANCED INPUTS BALANCED OUTPUTS INPUT 2 1 1 2 2 3 3 1 GND 2 HOT 3 COLD 1 2 3 PUSH PUSH PUSH PUSH MIXER ON MUTE SGN LIM PHASE 90Hz ...

Page 11: ...Weise installieren um jede Gefahr für Personen oder Sachschäden zu vermeiden Um gefährliche Situationen zu vermeiden nie mehrere Lautsprecher ohne angemessene Abspannsysteme aneinander anschließen Zum Fliegen verwenden sie nur das SRK09 original dBTechnologies Fly Kit Bei Verwendung im Freien sollte man darauf achten das die Lautsprecher vor witterungseinflüssen wie Sturm Regen Hagel Schnee usw ge...

Page 12: ... aggiuntivi non idonei allo scopo Contact dBTechnologies for accessories to be used with speakers Will not accept any responsibilty when inappropriate accessories or not suitable additional devices are used Kontaktieren sie dBTechnologies für passendes Lautsprecherzubehör Falls unpassendes Zubehör verwendet wird wird jegliche Haftung ausgeschlossen Contact dBTechnologies pour les accessoires à uti...

Page 13: ...29 INSTALLAZIONE INSTALLATION INSTALLATIONEN INSTALLATIONS In appoggio impilato Groundstack stacked In appoggio Groundstack ...

Page 14: ...30 In appoggio con flybar opzione DRK 10 Groundstack with flybar DRK 10 option Escluso DVA S09dp Bianco DVA S09dp White excluded DVA S09dp White ausgeschlossen DVAS09dp Blanc exclus ...

Page 15: ...31 Kit staffe opzione SRK 09 Kit stirrups SRK 09 option In appoggio con kit staffe Groundstack with kit stirrups ...

Page 16: ...32 Appeso con kit staffe opzione SRK 09 e flybar opzione DRK 10 Hang with stirrups kit SRK 09 option and flybar DRK 10 option ...

Page 17: ... su asta per Groundstack with stand adaptor Per supporto asta Stand adaptor Opzione DSA 4 DSA 4 Option In appoggio Floor stack Escluso DVA S09dp Bianco DVA S09dp White excluded DVA S09dp White ausgeschlossen DVAS09dp Blanc exclus ...

Page 18: ...of 4 wheels DWK 20 option In appoggio a pavimento con supporto asta provvisto di piedi Groundstack to floor with stand adaptor with feet Escluso DVA S09dp Bianco DVA S09dp White excluded DVA S09dp White ausgeschlossen DVAS09dp Blanc exclus ...

Page 19: ...A E B INDUSTRIALE s r l Via Brodolini 8 40056 Crespellano Bo ITALIA Tel 39 051 969870 Fax 39 051 969725 Internet www dbtechnologies com E mail info dbtechnologies aeb com ...

Reviews: