![DV Systems D20 Installation And Start-Up Manual Download Page 27](http://html.mh-extra.com/html/dv-systems/d20/d20_installation-and-start-up-manual_2543813027.webp)
42 1/2
27 3/4
1:20
SALES-ENGINEERING DRAWING
1
D20 SCREW COMPRESSOR
SCALE
D20, D20VSD
10/03/13
DATE
T. VOICU
CHECKED BY
DECIMAL DIMENSION:
DRAWN BY
1 OF 1
ANGLES:
*UNLESS OTHERWISE SPECIFIED
ALL DIMENSIONS ARE IN INCHES
FRACTIONAL DIMENSIONS:
DESCRIPTION OF DRAWING
DRAWING NO.
SHT NO REV.
NAME OF PROJECT
1/32
.005
IMPORTANT NOTE: This print is the confidential property of DV SYSTEMS, INC.
It is not to be used or reproduced in any manner, nor submitted to other parties for
examination without the prior approval of DV SYSTEMS, INC.
EMERGENCY STOP
1" NPT
AIR OUTLET
COMPRESSED
FORKLIFT
ACCESS
18
44 1/2
29
2
1/2" HOLES
30
43
COOLING
AIR INLET
REMOVABLE
REAR PANEL
7 5/8
23
5
POWER IN
OPENING FOR 3/4" CONDUIT
EXHAUST
AIR OUTLET
7
20
5
WEIGHT
LBS
SERVICE DOORS
3540
REMOVABLE
120
PSI
145
PSI
20
MOTOR
100-110
AMPS
82
D20,
73
D20VSD
F) MAX.
C (105
subject to change without notice.
its product designs, as a result, specifications may be
DV SYSTEMS INC. is committed to continually improving
F) MIN. AND 40
C (50
3. AMBIENT CONDITIONS: 10
TO A SOLID LEVEL FLOOR USING ISOLATOR PADS
2. COMPRESSOR MUST BE LEVEL AND ANCHORED DOWN
OBJECTS FOR PURPOSE OF COOLING AND SERVICING
1. MAINTAIN 3 FEET DISTANCE FROM WALLS AND OTHER
INSTALLATION REQUIREMENTS
8477
71
200V, 53A
230V, 46A
460V, 23A
575V,18.4A
120
ASD-100
10
980
MODEL
NO.
HP PRESSURE
PSI
SCFM
TEFC
MOTOR
RPM
AIR END
RPM
NOMINAL
SOUND @
1 METRE
dBA
MOTOR
VOLTAGE
AIR
RECEIVER
GAL.
DRYER
FILTER
ELEMENT
MICRON
DISCONNECT FUSE TABLE
VOLTAGE
PHASE
VARIABLE SPEED
FIXED SPEED
FUSE TYPE
FUSE AMP FUSE TYPE FUSE AMP
200
3
J
FAST-ACTING
(DFJ)
80
TIME-DELAY
90
230
75
460
50
40
575
35
30