DV Mark DV Micro 50 Owner'S Manual Download Page 5

5

15) AC POWER SOCKET 

Make sure the unit is grounded; all three terminals of the AC power plug must be connected to avoid any injury to the user 

or damage to the unit

.

16) VOLTAGE SELECTOR

 The DV MICRO 50 features a 120V/240V Voltage Selector to use the amp in countries with different voltages, so 

make sure the switch on the rear panel is on the correct voltage before connecting it to the AC power, and the fuse is the right value for that 

voltage (This selector is not available on the 100V version).

Please change the voltage/fuse values label located near the voltage selector matching the voltage/fuse values when you need to change the 

voltage of the unit.

17) FSW

 1/4” MONO jack for connecting a SINGLE 

footswitch to switch between Clean and Lead 

channels.

18) GROUND LIFT

 Occasionally, when you’re 

playing live and using the Line Out (18), the 

soundman will detect a hum from your amp’s signal. 

This is often due to a ground problem related to your 

power source; You will likely eliminate this hum 

simply flipping the GND Lift switch.

19) LINE OUT

 This balanced XLR output sends a 

balanced signal to the mixing console or snake in 

live and studio situations. The Line Out signal is 

post-EQ and post-reverb

20) SPEAKER OUT

 The two speaker ouputs provided for speaker cabinet connections are wired in parallel and total minimum impedance load for the 

amp is 4 ohms, so you can connect one or two 8 ohms speakers or only one 4 ohms speaker. 

Use speaker cable (not instrument cable)..

REAR PANEL

SPEAKER OUT

MIN LOAD 4Ω

LINE OUT

FSW

VOLTAGE

120

240

1

7

2

6

5

13

4

3

8

9

10

11

12

14

15

16

17 18 19

20