Owner’s Manual – Solar Water Heaters
19
H3165 029664 Rev. B
Gas Booster Installation
General:
An instantaneous gas water heater is to be
installed between the storage tank of the
water heater and the hot water outlets to
boost the water temperature as required.
The instantaneous gas water heater is to be
mounted and connected by the installer.
Electrical Requirements:
A switched general purpose socket outlet
(GPO) is required to be located within
1.2 metres of the instantaneous gas water
heater. If the GPO is not protected from the
weather, it is to have a minimum degree of
protection of IP33. Refer to AS/NZS 3000 for
further information.
It is recommended a double GPO is installed
to provide power to the solar controller and
the instantaneous gas water heater.
Installation:
An Installation Manual and Owner’s Guide is
supplied with the instantaneous gas water
heater.
Please refer to these documents for
installation instructions.
Temperature Setting:
To inhibit the growth of
Legionella
bacteria,
the instantaneous gas water heater must be
set at 70°C or above.
Please refer to the instantaneous gas water
heater Installation Manual for temperature
setting instructions.
Bridge A
must
be installed in the remote
controller terminals located behind the front
cover of the water heater. This will set the
water heater to 75°C.
A remote controller must
not
be installed
with the water heater as this will enable the
set temperature to be adjusted
This page only applies to
Gas
Boosted Solar Water Heater Models.