DC 2900, 17
Part No 94164-A
Problem
Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
The motor stops directly
Incorrect fuse.
Change to correct circuit.
after starting.
Fan runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
DC 2900c
No plastic sack on the
Mount the correct sack.
cyclone.
DC 2900a
The container is not
fi
rmly
Secure the container.
attached to the bottom of
the cyclone.
Fan runs but poor suction.
Hole in the hose.
Change or repair hose.
Plugged
fi
lter.
Clean or change
fi
lter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
Machine blows dust.
Filter is perforated or has
Check the
fi
lters and change
come loose.
if necessary.
Abnormal sound from
Order service.
machine.
TROUBLE SHOOTING
Warranty
The warranty period for this machine is two years
and covers manufacturers faults. The warranty is
valid under the condition that the machine is used
under normal conditions on the task for which it was
designed and is maintained properly.
Normal wear is not covered by this warranty. Service
performed by other than Dustcontrol or its authorized
agent voids automatically the warranty. No other
warranty express or implied is applicable.
Description
Part
no
Plastic sack, standard
42702
Fine
fi
lter, cellulosa with
integrated
fi
lter cover
42029
Other accessories, see Dustcontrol catalogue.
Accessories
Description
Part
no
Fine
fi
lter, polyester with
integrated
fi
lter cover
42028