![Dustcontrol DC 2800 H Asbest Original Instructions Manual Download Page 14](http://html1.mh-extra.com/html/dustcontrol/dc-2800-h-asbest/dc-2800-h-asbest_original-instructions-manual_2543276014.webp)
DC 2800 H Asbest - 14
Part No 9497-D
Description
Part
no
Plastic bag
42285 H
Mikrofi lter
42027
Finfi lter Polyester
42028
Inlet plug
42250 H
Other accessories — see Dustcontrol catalo-
gue.
Accessories
Warranty
Th
e warranty period is two years for single shift operation
or equivalent time with multishift operation. Th
e war-
ranty covers manufacturing defects. Th
is warranty is null
and void for machines equipped with other than original
spare parts.
Warranty repairs must be performed by Dustcontrol or
their authorized agent. Unauthorized repairs forfeit this
warranty.
Problem Fault
Solution
Motor will not start.
Machine not connected.
Make sure connection.
The motor stops directly
Incorrect fuse.
Change to correct circuit.
after starting.
Fan runs but no suction.
Hose not connected.
Connect the hose.
Hose plugged.
Find and remove block.
The container is not fi rmly
Secure the container.
attached to the bottom of
the
cyclone.
No plastic sack on the
Mount the correct sack.
cyclone.
Fan runs but poor suction.
Hole in the hose.
Change or repair hose.
Plugged
fi lter.
Clean or change fi lter.
Hose too long or too small.
Change the hose.
Hose is kinked.
Check and free.
Machine top is mounted
Adjust the mounting.
incorrectly.
Dust is packed in the
Take off the top and clean
cyclone.
out.
Machine blows dust.
Filter is perforated or has
Check the fi lters and change
come loose.
if necessary.
Abnormal sound from
Order service.
machine.