Dustbane Floor cleaner Manual Download Page 7

6

Troubleshooting:

The spray is weak or there is no spray.

  The pump does not operate at full fl ow if there is 

air in the system.  Air can enter the system from several sources:

Out of water - fi ll the water reservoir and prime the system.

Out of chemical - replace the chemical container and prime the system.

Foot valve is clogged - clean or replace the foot valve in the reservoir.  To access the foot 

valve, remove fi ll port cap.  Pull water pick-up assembly out through fi ll port.  The foot 

valve is mounted on the end of the water pick-up assembly, and is designed to be re-

moved without tools.  See Fig. H.

Leak in one of the fi ttings.  Remove the cart top and fi nd the source of bubbles.  Correct 

the leak.

Battery is low, check battery life indicator, if necessary, recharge.

Pump pulses.

  There is a pressure switch in the pump.  If the pump is pulsing, this switch is 

cycling and the life of the pump will be greatly reduced.  Have the pump serviced.

Pump not running.

Battery is dead, recharge. 

Loose battery connection, check that both terminals are connected. 

Note:

- The pump does not contain any 

 eld serviceable parts.

  It should run for 800 to 1000 hours 

with no maintenance needed.  If leaks occur in the pump, it needs to be replaced.

-

The pump is 

 tted with a non-adjustable, factory installed, regulator.  This regulator is 

preset at the factory and should not be adjusted.

1.

a.

b.

c.

d.

e.

2.

3.

a.

b.

7

Fig. H

Water pick up assembly

(accessed through water fi ll port)

Foot valve

Summary of Contents for Floor cleaner

Page 1: ...Parts and Operations Manual Manuel de pièces et d opérations Clean and Fast Washroom Cart Code 50932 Serial _______________________ Date of Purchase ________________ More info www dustbane ca 11 2010 ...

Page 2: ...chemicals in accordance with manu facturer s instructions observe safety and handling instructions of the chemical manufacturers equipment after each use to maintain proper operation Unit with integral 12 5 gallon water reservoir Battery charger installed Spray attachment w 2 nozzles installed 15 ft discharge hose installed 2 Bottle holders for 1 gal rectangular bottles 2 Bottle holders for 1 gal ...

Page 3: ...ty easier This unit includes the following features 15 ft discharge hose Locking casters Spray attachment with two nozzles solution and rinse Storage for spray bottle Fresh water reservoir 12 5 Gal Chemical bottle holder Top Easy roll wheels 3 Tap style drain Sign hanger Battery Charger On Off Switch Battery Life Indicator ...

Page 4: ...014 purple 32 1 0 010 pink 64 1 Fig B Fig C 4 Chemical B Check valve metering tip holder Metering Tip Initial Set up Chemical A Remove any items sitting on the cart top Remove cart top by lifting near the chemical bottles See Fig B Remove tubing from checkvalve meter ing tip holder Push the selected metering tip into meter ing tip holder See Fig C Replace tubing Connect the red wire to the red ter...

Page 5: ...ositions on select valve See Fig G Turn the power switch on The pump should run for a short time then stop The pump will run until the discharge pressure reaches the factory set point The pump will then turn off until the trig ger on the spray attachment is activated Direct the spray nozzle into a drain or other con tainer and pull the trigger Run until a steady spray pattern is established withou...

Page 6: ...ly dis charge the battery before recharging NOTE Failure to follow this procedure after use will void the warranty on the pump 1 2 3 4 5 6 Maintenance The power switch is lighted when it is in the ON position The pump will run when the trigger on the spray attachment is pulled and stop when it is released The rollover valve on the outlet of the spray attachment selects between the two attached spr...

Page 7: ...s Remove the cart top and find the source of bubbles Correct the leak Battery is low check battery life indicator if necessary recharge Pump pulses There is a pressure switch in the pump If the pump is pulsing this switch is cycling and the life of the pump will be greatly reduced Have the pump serviced Pump not running Battery is dead recharge Loose battery connection check that both terminals are...

Page 8: ...placement black 1 9 H10092252 On off switch replacement kit 1 10 H10091867 Caster replacement kit 2 11 H10091866 Wheel replacement kit 2 12 H10091861 Fill port cap 1 13 H10092217 Sign hanger 1 14 H10092258 Mop clips 2 15 H10092256 Bottle holder round 2 16 H10092257 Bottle holder rectangular 2 17 H90084615 Tap style drain 1 18 H690014 Metering tip kit 1 19 H10076302 Foot valve EPDM 1 20 H10092251 C...