background image

 

 

Habitat 100V 

 

User Manual 

Version 01/2021 REV1.0 - IV812EN 

 

 

Summary of Contents for Habitat 100V

Page 1: ...Habitat 100V User Manual Version 01 2021 REV1 0 IV812EN...

Page 2: ......

Page 3: ...ation signs 7 3 3 Specifications 8 3 4 Scope of delivery 9 3 5 Function 9 4 How to use 10 4 1 Assembling 10 4 2 Positioning 11 4 3 Switch air purifier on and off 12 4 4 Daisy chain operation 13 5 Main...

Page 4: ...ents such as offices schools restaurants bars stores or banks and making the environment safer The air disinfection system with UV C technology is highly efficient whisper quiet and can be personalize...

Page 5: ...ock or impair the air circulation of the device with objects Do not place any objects on the device Do not place flammable substances near the device Do not use the device together with chemical and o...

Page 6: ...nual Version 01 2021 REV1 0 3 Description 3 1 Overview Fig 1 Habitat 100V overview 1 membrane suction surface 2 core unit 3 pedestal 4 top unit 5 air outlet 6 handle 7 output socket 8 input socket 9 s...

Page 7: ...EV1 0 7 3 2 Information signs Fig 2 Information signs on the device 1 name plate 2 output socket information sign Fig 3 information signs behind maintenance cover 1 UV light warning sign 2 maintenance...

Page 8: ...25 IP Code IP20 max volumetric flow m3 h 50 max volume dB A 35 wavelength UV C source nm 254 life span UV C source h ca 9000 room temperature range C 20 50 humidity range 0 70 max altitude m MSL 2000...

Page 9: ...antiviral coating renders bacteria particles germs and viruses innocuous Channels inside the panel forward the absorbed air on into the core unit 2 Disinfection The contaminated air is disinfected in...

Page 10: ...2021 REV1 0 4 How to use 4 1 Assembling Get assistance from other people when assembling heavy parts 1 Connect the pedestal 1 to the main unit 2 Use the four included countersunk screws 3 2 Stick the...

Page 11: ...er Manual Version 01 2021 REV1 0 11 4 2 Positioning Consider the orientation of the suction surface within the room Make sure the suction surface is not facing any walls Do not block or restrict air c...

Page 12: ...vices 0 40 0 100 12 2 20 80 100 200 25 4 80 120 200 300 38 6 120 160 300 400 50 8 160 200 400 500 63 10 Tab 2 Recommended number of devices per surface and person with room height of 2 5 m 4 3 Switch...

Page 13: ...utput socket 5 input socket 6 power cord 7 switch air purifier ON OFF 1 Position main device and desired number of additional devices 2 Connect first additional device to main device Plug daisy chain...

Page 14: ...lower module defective Replace both UV C lamps of lower module UV C lamps of upper module defective Replace both UV C lamps of upper module UV C lamps of both modules defective Replace all lamps of b...

Page 15: ...nd disconnect the power cord 1 2 Remove the maintenance cover 2 on the back side of the core unit The maintenance cover is attached magnetically 3 Unscrew the Phillips head screws 3 to remove the defe...

Page 16: ...ation Remove defective lamps from their socket Dispose of defective and unused lamps properly 6 Push the red latch 6 on the lamp socket as indicated in the illustration Insert new lamps 8 into their s...

Page 17: ...sion 01 2021 REV1 0 17 9 Reattach the maintenance cover 2 to the back side of the core unit 10 Connect the power cord 1 5 3 Replace fuse 1 Disconnect the power cord 1 2 Remove the maintenance cover 2...

Page 18: ...1 REV1 0 3 Use a flat screwdriver to unscrew the fuse holder cap 3 counterclockwise 4 Pull the defective fuse 4 from the fuse holder cap 5 Insert new fuse 5 into the fuse holder cap Only use an origin...

Page 19: ...t 100V 5 Maintenance and Troubleshooting 2021 Durst Phototechnik AG User Manual Version 01 2021 REV1 0 19 7 Reattach the maintenance cover 2 to the back side of the core unit 8 Connect the power cord...

Page 20: ...mber illustration Phillips head screws for lamp cover M3x6 1127188 countersunk screw for pedestal M5x12 1127021 UV C lamp 1873861 fuse 1860084 felt protector kit 1344466 retaining plates for UV C lamp...

Page 21: ...ical advice repairs or spare parts Europe Durst Phototechnik AG Julius Durst Str 4 39042 Brixen Italy P 39 0472 810125 service it durst group com durst group com Germany and Benelux Durst Image Techno...