1015100100L02 1910V003
15
i
Protect the unit against moisture, dirt and ex-
treme temperatures during transport (refer to
the section on "Ambient conditions").
i
Only store the unit when it has been com-
pletely emptied.
9.2 Switching the unit on/off
10
8
9
5
9 On/Off switch
i
The unit is switched on by pressing the on/off
switch (9).
The unit starts up and the pressure vessel is
filled. When the cut-off pressure is reached
the unit switches off automatically.
i
The unit is switched off by pressing the on/off
switch (9) again.
Maximum operating pres-
sure:
8 bar
Switch-on/cut-off pressure: 5 /7 bar
9.3 Start-up cycles
The motors in the compressor stations are de-
signed for 10 starts/stops per hour. More fre-
quent switching will lead to increased wear.
9 Operation
Prior to working on the unit or in case of
danger, disconnect it from the mains.
DANGER
Risk of electric shock due to defec-
tive cable connections and risk of
burns due to hot surfaces if the unit
is operated with the cover open.
During operation, the unit is under a live
voltage and its surfaces get hot.
i
The cover of the unit must be closed
during operation.
i
Regularly check cable connections for
damage.
9.1 Taking out of use
Taking the unit out of use
If the unit is not to be used for a prolonged peri-
od of time, we is recommend that it be decom-
missioned.
i
Switch on the unit and wait until the cut-off
pressure is reached (see "4 Technical data").
i
Switch off the unit.
i
Disconnect the unit from the mains power
supply and secure it so that it cannot be
switched on inadvertently.
i
Release all of the pressure from the pressure
vessel. To do this, pull the trigger of the com-
pressed air pistol until the unit is depressur-
ised.
i
Disconnect the compressed air pistol with
hose from the quick-release coupling of the
unit.
Before taking the unit back into opera-
tion, have a service carried out and the
filter replaced by a service engineer/tech-
nician qualified by Dürr Technik.
Storage of the unit
WARNING
Risk of explosion of the pressure
tank and pressure hoses
i
The pressure tank and the pressure
hoses must be vented before they are
stored or transported.
Usage
EN