CAUTION: LPG must be shut off when using gasoline!
CAUTION: Gasoline must be shut off when using LPG!
CAUTION: Disconnect all electrical loads from the generator before attempting to
start!
WARNING:
Operating the starter motor for more than 5 seconds can damage the
motor. If the engine fails to start, release the switch and wait 10 seconds before
operating the starter again.
STARTING THE GENERATOR
Shut breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
1.
Starting the Generator Using Gasoline
Turn gas valve on
Close choke
Start the generator
The gas valve is located above the recoil start on the bottom
of the fuel tank. Rotate the valve clockwise to the vertical
position to turn on the gas supply.
The choke lever is located above the air filter to the right
of the recoil start. Slide the lever to the left to cut the air
supply and allow more gas into the engine to start.
The engine switch is located on the left side of the front
power panel. Press the switch up to the “START” Position.
2.
3.
4.
27
Allow switch return to RUN
When the engine starts, allow the engine switch to return to
the “RUN” position.
5.
Open choke
Push the choke to the OPEN position as the engine warms up.
6.
26