STARTING THE GENERATOR
30
Starting the Generator Using Gasoline
Shut breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
1.
Turn gas valve on
Close choke
Start the generator
The gas valve is located above the recoil start on the bottom
of the fuel tank. Rotate the valve counterclockwise to the
vertical position to turn on the gas supply.
The choke lever is located above the air filter to the left of
the recoil start. Slide the lever to the left to cut the air supply
and allow more gas into the engine to start.
The engine switch is located on the left side of the front
power panel. Flip the switch up to the “START” position.
2.
3.
4.