STOPPING THE ENGINE
To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal conditions, use
the following procedure.
1.
Move the circuit breaker to the OFF position.
CIRCUIT
BREAKER
OFF
ON
2 Turn the engine switch to the OFF position.
1 Turn the AC circuit breaker to the OFF position. Disconnect DC battery charging cables.
In normal use:
To stop the engine in an emergency, move the engine switch to the OFF position.
In an emergency:
Stopping the Engine
When the engine starts, allow the engine switch to return to the ON position
.
be recharged
.
If the speed of the starter motor drops after a period of time, it is an indication that the battery should
release the switch and wait 10 seconds before operating the starter again
.
Operating the starter motor for more than 5 seconds can damage the motor. If the engine fails to start
,
3 Turn the off the propane gas supply.
b. If the engine is cold (the unit was not run recently) start with the choke "OPEN".
7 Turn the engine key switch to the START position and hold it there for 5 seconds, or until the
engine starts.
Decompression
Valve / Regulator
Connect to propane
gas supply.
i. Wait 30 seconds and then push the choke lever all the way to the "OPEN" position.
a. If the engine is warm (the unit was run recently) start with the choke half open.
6 The choke operates differently on propane gas.