5
GENERATOR COMPONENTS
Please familiarize yourself with the locations and functions of the various components and
controls of your generator.
(1) Air cleaner-
a removable, cleanable, sponge-like element that limits the amount of dirt
pulled into the engine.
(2) Choke lever-
Adjusts the amount of air let into the engine.
(
3) Fuel Gauge-
Indicates the amount of fuel in the tank.
(4) Fuel Cap-
Access to the fuel tank for adding fuel.
(5) Circuit Breaker-
Reset switch that protects the generator from electrical overload.
(6) 120/ 240 Volt AC Receptacle-
Use to connect electrical devices that run 120 and/or
240 Volt, 60Hz, single phase, AC current (NEMA L14-30).
(7) Ground Terminal-
Connect grounding wires here to properly ground unit.
(8) 120 Volt AC Receptacle-
Use to connect electrical devices that run 120 Volt, 60 Hz,
single phase, AC current (2
×
duplex GFCI).