CAUTION: Never place any type of storage cover on the generator while it is still
hot.
When transporting your generator:
●
Empty the gas tank (see “Emptying the Gas Tank” in the “Maintenance” section).
●
Disconnect the spark plug.
●
Do not obstruct any ventilation openings & keep the generator in a cool dry area.
Storage and Transportation
51
Storage Period
Storage Preparation
If you plan on starting
the same day.
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the key.
4.
Store.
If you plan on starting
the unit again within
30 days.
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the fuel valve.
4.
Allow the unit to stall out.
5.
Turn off the key.
6.
Add fuel stabilizer to the gas remaining in the tank.
7.
Store.
If you do not plan to
start the unit for
longer than 30 days.
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the fuel valve.
4.
Allow the unit to stall out.
5.
Turn off the key.
6.
Drain the fuel tank (See “Emptying the Gas Tank” in the “Maintenance” section)
7.
Drain the carburetor
a.
Remove the drain bolt from the carburetor.
b.
Drain the small amount of remaining fuel from the carburetor bowl.
8.
Oil the cylinder
a.
Remove the spark plug.
b.
Put 2 tbsp. of 10w30 motor oil directly into the spark plug hole
c.
Pull the recoil start one time.
d.
Replace the plug.
9.
Remove the battery and place on tender indoors.
Summary of Contents for 991772K1
Page 2: ......
Page 5: ......
Page 38: ...38 ...
Page 41: ...MAINTENANCE LOG Date Generator Hours Maintenance Performed 41 ...
Page 60: ...WIRING DIAGRAM 60 ...
Page 61: ...61 ...
Page 63: ...63 ...
Page 65: ......
Page 66: ...5800 Ontario Mills Parkway Ontario CA 91764 United States 844 DUROMAX ...