Gas Leakage Testing
After install the gas supply system, and the Gill is well fixed to the enclosure:
1
,
Before lighting the grill, test all connections by brushing on an
approved non-corrosive leak-detection solution. Bubbles will
show a leak.
2
.
If a leak is found, turn the tank valve off and do not use the
grill. Contact a qualified gas technician to make repairs.
Install The Battery
1.
The igniter battery is not factory installed. A “AA” size alkaline
battery is located in the accessory box on the grill grate.
Install battery at this time following the instructions in
“Replacing the Igniter Battery” section.
2.
After above procedure then go to “Check and Adjust the Burners”
section.
Check and Adjust the Burners(See page 15)
Grill Use( See page 16,17)
Disconnecting The Grill.
Disconnect 20 lb LP gas fuel tank (if present) and remove the 20 lb LP gas
fuel tank from the grill cabinet.
1.
check that the 20 lb LP gas fuel tank is in the “Off” position. If not, turn
the valve clockwise until it stops.
2.
Using your hand, turn the gas pressure regulator/hose assembly
counter- clockwise to disconnect to the 20 lb LP gas fuel tank.
Warning:
Storage of an outdoor cooking gas appliance indoors is permissible only if
the cylinder is disconnected and removed from the outdoor cooking gas
appliance.
13