Connecting the throat plate slide interrogator
10
Additional Instructions 867 M-TYPE - 00.0 - 05/2018
3 Connecting the throat plate slide interrogator
Order
1. Assemble the throat plate slide interrogator (
2. Connect the throat plate slide interrogator.
3. Test functionality (
Information
If not yet present on the machine, the adapter (part no.
0867 592224
)
must be assembled first.
The plug connection
X6
(IN) of the circuit board must ALWAYS be
connected to the machine distributor. The corresponding cable is
included.
Depending on the type of machine distributor, the plug connection and
setting must be established:
WARNING
Risk of injury from sharp and moving parts!
Crushing, cutting and punctures are possible.
Do not connect the throat plate slide interrogator
unless the machine is switched off and de-energized.
Disconnect the machine from the power supply
before connecting the interrogator.
NOTICE
Property damage may occur!
The cables may be crushed, kinked and cut.
Make sure not to guide the cables over sharp edges and moving
parts and do not kink or crush the cables.
Machine distributor
Plug
Comment
9850 688001 (DA178)
X15
J1 must be open (OFF)
9850 867000 (DA174)
X26
J2 must be open (OFF)
9850 867020 (DA289)
X29
S2 must be open (OFF)
9850 838000 (DA199)
X23
S2 in position 1-OFF; 2-ON; 3-OFF