4.14 Selecting Output Elements
Caution Risk of Injury !
During the function test do not reach into the running machine.
Choose your position so that no injury is possible (e.g. Function test
s17: Table back).
The program checks the functioning of an output element.
–
Set the " Program " switch to " 64 ".
–
Press the " STOP " key.
The program is activated.
–
Set the " Program " switch to the output element.
–
Press the "
Σ
" key.
The selected output element is turned on.
–
Press the "
Σ
" key.
The selected output element is turned off.
Output
Designation
Element
s17
Table back
s18
Table free
s19
Thread tension release
s9
Blower from the right
s10
Blower from above
s25
Smoother
s28
Shears
s29
Form set slewing
s30
Pressure increase for the thread clamp
s31
Thread chain release
s32
Form set closing
4.15 Positioning the Machine Head in the 2nd Needle Position
This program positions the machine head in the 2nd position (needle
up).
–
Set the " Program " switch to " 66 ".
–
Press the " STOP " key.
The program is activated. Display " SW? "
–
Set the drive rpm with the " Program " switch to " 01 "... " 13 ".
01 = Minimum rpm
13 = Maximum rpm
–
Press the "
Σ
" key and hold down.
The drive runs at the selected rpm. The current rpm appears after
a few seconds.
After release of the "
Σ
" key, the needle positions in the 2nd
position (needle up).