background image

Pre-installation data sheet Zencha_22.07.1

Height 

[mm]

Bathtub
Whirltub

Technical specifications

Net 

weight 

[kg]

Floor load 

[kg/m

2

]

Shipping weight 

[kg]

Shipping dimen-

sions l x w x h 

[cm]

Drain 

connection 

[mm]

Inlet connection 

(OG) 

[inch]

Whirlsystem

Model-No.

Pre-installation Zencha

Hot water connection
Cold water connection
Drain connection
Electricity connection

600
600

138,2

348

174,6

206,5 x 109 x 72 40 / 50

-

-

700463 00 0 00 0000

149,2

355

185,2

206,5 x 109 x 72 40 / 50

-

Air-System

760463 00 0 AS 0000

#700463 / #760463

|< 900 x 1800 >|

H:
C:
D:
EC  :

500

1800

450

25

25

280

850

900

D

EC

C

H

6

Summary of Contents for Zencha

Page 1: ...Pre installation Data Sheet Bathtubs and Whirltubs Zencha ...

Page 2: ...y a licensed electrician SAFETY INSTRUCTIONS Incorrect handling transport may result in product damage The metal frame and whirl system are not resilient Never hold by the metal frame or whirl system Improper transport can cause damage to the product and or property damage e g leaks Wear appropriate protective clothing Avoid knocks Risk of product and or property damage The breach of local and cou...

Page 3: ...ended area MAINTENANCE OPENINGS AND AIR SUPPLY The air supply for the whirl system ventilation grille ventilation slot must not be covered ELECTRICAL INSTALLATION DANGER Risk of fatal electric shock Disconnect the power supply while working on the electrical components The device must be earthed Earthed appliances must be permanently connected to fixed wiring Connect the device only to the designa...

Page 4: ... with the location of the operating unit The back massage is located at the head end depending on the whirl system Custom made designs available on request In such cases we will require a drawing showing the desired layout Duravit will confirm whether the desired layout can be implemented Legend Only Combi Systems The number of operating elements is based on the whirl system and the additional mod...

Page 5: ...Drain connection mm Inlet connection OG inch Whirlsystem Model No Pre installation Zencha Hot water connection Cold water connection Drain connection Electricity connection 600 600 120 357 156 4 206 5 x 109 x 72 40 50 700462 00 0 00 0000 131 365 167 0 206 5 x 109 x 72 40 50 Air System 760462 00 0 AS 0000 700462 760462 850 x 1600 H C D EC 450 1600 450 90 90 280 620 850 D EC C H 5 ...

Page 6: ...ain connection mm Inlet connection OG inch Whirlsystem Model No Pre installation Zencha Hot water connection Cold water connection Drain connection Electricity connection 600 600 138 2 348 174 6 206 5 x 109 x 72 40 50 700463 00 0 00 0000 149 2 355 185 2 206 5 x 109 x 72 40 50 Air System 760463 00 0 AS 0000 700463 760463 900 x 1800 H C D EC 500 1800 450 25 25 280 850 900 D EC C H 6 ...

Page 7: ...kg Shipping dimen sions l x w x h cm Drain connection mm Inlet connection OG inch Whirlsystem Model No Pre installation Zencha Hot water connection Cold water connection Drain connection 630 132 5 380 181 9 197 x 148 x 72 40 50 700464 00 0 00 0000 700464 760464 1250 x 1250 H C D 4 8 0 50 110 110 700 ø 1 2 5 0 C H D ø450 1 1 0 1 1 0 7 ...