![DURAVIT SensoWash Starck Mounting Instructions Download Page 5](http://html.mh-extra.com/html/duravit/sensowash-starck/sensowash-starck_mounting-instructions_2542027005.webp)
Electrical installation
Position of electrical / water connection with
wall-mounted WC
Pre-Installation
>
Lay a permanent power supply line:
•
Connect a separate upstream circuit breaker
•
Connect an upstream residual current device (RCD)
separating all poles
DAngEr!
risk of fatal electric shock.
>
Do not use any unearthed extension cables when
connecting the Shower WC.
20
Connecting the Shower WC (Diagram 20)
nOTE! Avoiding property damage.
>
Only connect the Shower WC to a socket with the
stipulated connected loads.
>
Ensure that the power plug is accessible to users
after the installation.
#610000 00 1 04 0100 Power supply
120V ~ 60Hz
Rated power 1.33 KW
#610000 00 1 06 0100 Power supply
110V ~ 60Hz
Rated power 1.06 KW
Circuit breaker
I
N
= 16 A
RCCB
I
N
= 30 mA
Protection type
IP X4
Position of electrical / water connection with
flor-standing WC
Cold water
DN 15(1/2")
Water pressure
0.07 - 0.75 MPa
(0.7 - 7.5 bar)
Water hardness
max. 2,4 mmol/l
nOTE!
>
Install a water water softener with water
hardness ≥ 2,. mmol/l (≥ 14° dH and/or
24° fH).
Water installation
Pre-Installation
>
Install the water connection and water outlet in the
specified areas.
DAngEr!
Health risk and potential product damage.
>
Supply the WC with cold drinking water from the main
water system.
>
Do not connect any waste water, grey water, industrial
water, sea water or other untreated or semi-treated
water.
10
Connecting water to a wall-mounted WC
(Diagram 10)
nOTE! Avoiding any malfunctions!
>
Only use the water supply hoses provided.
17
Connecting water to a free-standing WC
(Diagram 17)
nOTE! Avoiding any malfunctions!
>
Only use the water supply hoses provided.
IG ½”
..
23
0-320 mm
9“-12
⅝“
265-300 mm
10⅜“-11¾“
285-300 mm
11¼“-11¾“
IG ½”
21
0-230 mm
8
¼“-9
“
..
250-300 mm
9⅞“-11¾“
250-300 mm
9⅞“-11¾“
5
SensoWash Starck_MAL_US_56936/16.08.2
en
Summary of Contents for SensoWash Starck
Page 2: ...2 SensoWash Starck_MAL_US_56936 16 08 2 ...
Page 12: ...SPECIFICATION SensoWash Starck_MAL_US_56936 16 08 2 610000 1 12 ...
Page 13: ...SensoWash Starck_MAL_US_56936 16 08 2 2x 2x M6x42 11 9 3 2 1 7 6 5 4 8 9 13 ...
Page 14: ...SensoWash Starck_MAL_US_56936 16 08 2 1x 19 13 14 13 12 11 10 15 18 17 16 14 ...
Page 16: ...SensoWash Starck_MAL_US_56936 16 08 2 SPECIFICATION 1 2 2x M4x15 28 29 30 31 32 33 34 16 ...
Page 17: ......
Page 18: ......
Page 19: ......