These instructions are part of the Duravit
product and must be read carefully and kept
available at all times.
Target readership and qualifications
The product may only be installed by a
qualified plumber.
Explanation of the symbols
Link to the mounting instructions
in this section
Prompt to wear gloves
Optional settings
Technical data
Operating pressure
max. 1.0 MPa
Recommended
0.3 - 0.5 MPa
Test pressure
1.6 MPa
1 MPa = 10 bar = 145 PSI
Hot water temperature
max. 60 °C
Safety instructions
Cut and crushing injuries
> Wear gloves when installing the product.
Product and/or property damage
> Observe the local installation regulations
and any country-specific standards at all
times.
> Equalise pressure differences between cold
and hot water connections.
> Observe the manufacturer’s instructions for
installation with continuous flow heaters.
Mounting instructions
7
+
11
Using silicone without acetic acid
> Use alkoxy-based silicone.
5
MAL_57930/22.03.1