Duratuf Garrison PL84 Assembly Instructions Manual Download Page 9

 

 

ASSEMBLE

 

SIDE PANELS

 

8

 

BOTTOM PLATE

 

BOTTOM PLATE

 

SELECT:

 

 

2 x 1.905 m Side Wall Sheets (Angled)

 

2 x 1.935 m Side Wall Sheets (Angled)

 

2 x 1.965 m Side Wall Sheets (Angled)

 

2 x 1.522 m Top Plates (Red)

 

2 x 1.520 m Bottom Plates (Green)

 

72 x 30mm Galv Clouts

 

8 x Rivets

 

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING;

 

 

For sheds with Raised Base Plate option only (see page 6), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

.

 

BOTTOM PLATE

 

1857mm

 

1948mm

 

15mm

 

BOTTOM PLATE

 

1857mm

 

1948mm

 

Second Side

 

Panel

 

STEP 1:

 

 

• 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat surface (corner 
cutouts to face as shown). 

Measurements between Top and Bottom 

plates are critical to ensure wall panels fit together.

 

STEP 2:

 

 

• 

Place 1 x 1.905m, 1 x 1.935m and 1 x 1.965m Side wall sheets on 
top of timber plates, with bottom of sheets flush with each other. 

 

 

• 

Rivet sheets together on overlaps as shown.

 

STEP 3:

 

 

• 

Nail wall sheets to the Top Plate at each end making 
sure that the top of the sheets are flush with the top of 
the Top Plate and the sides of the wall sheet overhang 
the Top Plate by approx 15mm as shown.

 

 

• 

Check that the Top Plate is straight then nail the wall 
sheet to the Top Plate, two clouts per pan (see 

fig. 1

).

 

STEP 4:

 

 

• 

Nail the wall sheets to the Bottom Plate at each end ensuring each 
side of wall sheets overhangs the end of Bottom Plate by 15mm. 
Check that the distance between the Top and Bottom Plates is 
correct. (As per diagram in step 1)

 

 

• 

Check that the Bottom Plate is straight then nail the wall sheets to 
the Bottom Plate, two clouts per pan (see 

fig. 1

).

 

Repeat with second side panel ensuring Top Plate is as shown.

 

 

fig.1

 

RIB

 

PAN

 

CLOUT

 

TIMBER PLATE

 

Standard Shed —

 

Bottom Plate will protrude below 

wall sheet by approximately 10mm. 

 

 

Raised base plate shed —

 

Wall sheet will protrude 

 

below the Bottom Plate by 20mm

.

 

15mm

 

15mm

 

1857mm

 

1948mm

 

15mm

 

RIVET

 

RIVET

 

RIVET

 

RIVET

 

BOTTOM PLATE

 

15mm

 

Summary of Contents for Garrison PL84

Page 1: ...ASSEMBLY INSTRUCTIONS PL84 BASE SIZE 2 520m x 1 520m...

Page 2: ......

Page 3: ...process needs to be adhered to to qualify for the steel warranty of your Duratuf Garrison shed Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as...

Page 4: ...1 980m 3 Back Wall 1 890m 5 Side Wall Angle 1 965m 2 Side Wall Angle 1 935m 2 Side Wall Angle 1 905m 2 Roof 1 720m 5 Door Sheet Narrow 1 940m 2 Door Sides 1 940m 2 Door Jamb 1 980m 2 Door Brace 1 200...

Page 5: ...ECK LIST INCLUDED IN PACK 2 DESCRIPTION QTY DIAGRAM Front Back Bottom Plates H4 Green 2 520 m 2 Front Back Top Plate H1 Red 2 520 m 2 Side Wall Bottom Plates H4 Green 1 520 m 2 Side Wall Top Plates H1...

Page 6: ...ION 2 ASSEMBLE DOOR QUICK OVERVIEW Top Plate Back Side Wall Sheets Barge Flashing Spouting Roof Sheets Top Plate Side Top Plate Front Bottom Plate Front Bottom Plate Side Back Wall Sheets Front Wall S...

Page 7: ...hrough from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bottom plat...

Page 8: ...m flashings and assemble door as shown Drill and rivet as per diagram STEP 4 On the back of the door place door braces in posi tion as shown in fig 3 Ensure that the top and bottom ends of the braces...

Page 9: ...with bottom of sheets flush with each other Rivet sheets together on overlaps as shown STEP 3 Nail wall sheets to the Top Plate at each end making sure that the top of the sheets are flush with the t...

Page 10: ...ts to the Top Plate at each end making sure that the top of the sheets are flush with the top of the Top Plate and that the sides of the wall sheets overhang the Top Plate by 15mm as shown Check that...

Page 11: ...e Plates are the correct distance apart and that the sides of the wall sheet overhang the Bottom Plate by 15mm Drill rivet Door Jamb Flashings to wall sheets using four riv ets equally spaced on each...

Page 12: ...Using 2 x 40mm screws screw Top Plates together in the corner Using 2 x 40mm screws 2 per join screw the Bottom Plates together in the corner STEP 2 Repeat Step 1 with the second Side Panel ensuring...

Page 13: ...Plates Rivet sheets together at overlaps with 2 x rivets per join STEP 2 Position the Roof Sheets with front overhang of 130mm at each end fig 1 Using 4 x 50mm Clouts predrill and nail the Roof Sheets...

Page 14: ...REMOVE ALL DRILL FILINGS FROM ROOF WALLS AND CHANNELS THOROUGHLY FAILURE TO DO THIS WILL RESULT IN CORROSION AND COULD THEREFORE VOID THE WARRANTY FIT PADBOLT Rivet Padbolt to door and keeper onto Do...

Page 15: ......

Page 16: ...less than 200g m2 as published by Branz Warranty certificate being returned to manufacturer within 21 days of purchase together with proof of purchase This warranty does not cover the following Faste...

Reviews: