background image

16

• 

The above accuracy specifications are specified in the same operating 

environment after keeping the instrument in a fixed state for at least one hour.

• 

If the instrument is exposed to an environment of high humidity during a period of 

storage, ensure that the instrument be kept in the same operating environment for 

at least two hours.

• 

Accuracy does not contain the tolerance of the thermocouple probe.

CLEANING & MAINTENANCE

• 

If there is dust on the terminal or the terminal is wet, it may cause measurement 

error.

• 

Switch off the power supply of the instrument and remove the test probes.

• 

Turn over the instrument and shake out the dust accumulated in the input socket.

• 

Wipe the outer cabinet with a damp cloth and a mild detergent.

• 

Do not use any chemicals, abrasives or solvents that may damage the instrument.

• 

Wipe the contacts in each input socket with a clean cotton swab soaked in alcohol.

REPLACING THE BATTERY AND FUSE
Battery

• 

Turn off the power supply of the instrument, and remove the probe on the 

instrument.

• 

Unscrew the two screws fixing the battery cover and remove the cover.

• 

Remove the old batteries and replace with new batteries of the same specification.

• 

Ensure that the batteries are inserted correctly, observing the plus and minus 

marks on both the batteries and compartment.

• 

Reinstall the battery and screws to their original position.

Fuse

• 

Turn off the power supply and remove the probes from the instrument.

• 

Unscrew the four screws holding the back cover from the four corners of the 

instrument and remove the cover.

• 

Remove the used fuse and replace it with a new fuse of the same specification.

• 

Ensure it is fitted securely into the safety clip.

• 

Reinstall the back cover and screws.

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF 

ELECTRICAL & ELECTRONIC EQUIPMENT.

When this product has reached the end of its life it must be treated as Waste 

Electrical & Electronics Equipment (WEEE).  Any WEEE marked products 

must not be mixed with general household waste, but kept separate for the 

treatment, recovery and recycling of the materials used.  Contact your local 

authority for details of recycling schemes in your area.

Made in China. PR2 9PP

V 1.0

CONNECTIVITY TEST

Range

Function

• 

Open circuut voltage is about 

0.5V

• 

Overload protection: 1000V DC 

or 750V AC (RMS)

Resistance of the measured circuit is 

less than 50Ω, the buzzer contained 

in the instrument will sound.

Summary of Contents for D03122

Page 1: ...1 MODEL D03122 DIGITAL MULTIMETER WITH T RMS USB...

Page 2: ...9 Measure Resistance 10 Measure Connectivity 10 Measure Capacitance 10 Measure Diode 11 Measure Temperature 11 Measure Transistor 11 Auto Power Off Function 12 Backlight Function 12 Data Hold 12 Gener...

Page 3: ...ves masks and flame retardant clothes etc to prevent being injured by electric shock due to exposed hazardous live conductors When measuring connect the zero line or the ground line first then connect...

Page 4: ...6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 Auto power off 8 DC indicator 15 Max Min Value Measurement 2 Simulation bar indicating rapid change trend 9 Resistance Frequency Unit 16 USB Interface Open...

Page 5: ...on selections 1 OFF 2 AC or DC Voltage Press Func to switch 3 AC or DC Voltage mV Press Func to switch 4 Frequency duty ratio Press Hz to switch 5 Resistance diode connectivity capacitance Press Func...

Page 6: ...perform the following steps In automatic ranging mode press the RANGE button the AUTO symbol will disappear from the display Press the RANGE button to increase the range When the maximum range is reac...

Page 7: ...n except OFF Press and hold the REL USB button for more than 2 seconds and the instrument will display the USB symbol to show that the data transmission function is enabled Press and hold the REL USB...

Page 8: ...electric shock or personal injuries Do not apply voltage exceeding DC 1000V or AC 750V RMS between the common terminal and the earth otherwise it may cause damage to the instrument electric shock or...

Page 9: ...mage to the instrument or equipment please check the fuse before measurement and use the correct input socket MEASURE RESISTANCE Scroll the rotary knob to press the FUNC button and switch to resistanc...

Page 10: ...the measurement result on the screen WARNING Before measuring resistance connectivity capacitance or diode please turn off the power supply and discharge all the high voltage capacitors otherwise it...

Page 11: ...rwise it may cause the instrument damage electric shock or personal injuries Caution Do not fold the thermocouple wire into an acute angle Repeatedly bending the wire over a period of time may cause t...

Page 12: ...the use of the backlight then replace the battery immediately DATA HOLD In the process of measurement if a held reading is required press the button the displayed value on the screen will be held Pres...

Page 13: ...oint the reading will stabilize 11 Power Requirement 4 x 1 5V AA batteries Dimensions 204x94x57mm LxWxH Weight About 410g inluding batteries AC VOLTAGE Range Resolution Accuracy Input impedance 10M 60...

Page 14: ...easurement the instrument should be cooled down after twice of the measurement time then enter small current measurement RESISTANCE Range Resolution Accuracy Open circuit voltage about 0 25V Overload...

Page 15: ...range range the input current should be increased with the increase of the measured frequency Input protection A mA range F600mA 1000V ultra speed fuse 10A range F10A 1000V ultra speed fuse Note Comp...

Page 16: ...r Remove the old batteries and replace with new batteries of the same specification Ensure that the batteries are inserted correctly observing the plus and minus marks on both the batteries and compar...

Reviews: