background image

6

• 

Slide a new tip down inside the retainer and refit 

onto the gun.

• 

Replace and tighten the knurled nut (finger tight 

only). 

 

 

 

Caution: 

Do not over tighten the nut as the element could be damaged.

NOTE:

 The additional tips supplied are sealed with solder when new. When the 

desoldering iron has reached operating temperature and the solder has melted, pull the 

trigger on the gun to extract the solder into the waste collector.

CLEANING

• 

Cleaning should only be done when the power is switched off and the irons are 

at room temperature. Use a damp cloth and a small amount of liquid detergent if 

necessary.

• 

Never submerse the desoldering gun, iron or control station in liquid or allow any 

liquid to enter the case.

• 

Do not use any chemicals, abrasives or solvents that could damage the 

desoldering gun, interconnecting leads and pipe, soldering iron or the control 

station.

• 

If the vacuum efficiency seems to be reducing, pull off the vacuum pipe from the 

control unit and unscrew the adaptor. Do not lose the sealing washer from inside 

the adapter. Pull out the filter pad from inside the connector on the control unit and 

examine for blockage. Replace with a new one if required (supplied).

SOLDERING IRON TIP REPLACEMENT

• 

Replacing the soldering iron tip should only be done when the iron is switched off 

and at room temperature.

• 

The tip can be changed or replaced by unscrewing the knurled nut barrel.

Caution

: Damage could occur if the iron is left on without the tip inserted.

• 

After removing the tip, blow out any remaining oxide dust that may have formed in 

the tip retaining area of the barrel. 

Warning

: Care should be taken to avoid getting dust in your eyes.

• 

Replace the tip and tighten the knurled nut barrel assembly with your fingers.

• 

Pliers should only be used to tighten the nut if loosening occurs when the iron is 

hot.

• 

Do not over tighten the nut as the element could be damaged.

Summary of Contents for D00674

Page 1: ...1 80W Soldering Rework Station Model D00674...

Page 2: ...a hazard Do not leave the soldering station unattended while it is powered on Never touch the soldering tip or the surrounding metallic parts before the soldering tip has cooled down completely Turn...

Page 3: ...der mounted on the side of the station Before using the soldering iron for the first time dampen the cleaning sponge and place it in the tray on the base of the iron holder Keep it damp during use Con...

Page 4: ...reater than 10 WAIT displays on the LCD To change from C to F press o C o F button The display shows C or F after the temperature figure Never file down the tips or attempt to clean using abrasives If...

Page 5: ...ad and spring plate in position Remove the filter pad and spring plate and empty out the waste from the reservoir Replace the spring plate and filter into the rear end of the tube and re insert into t...

Page 6: ...n or the control station If the vacuum efficiency seems to be reducing pull off the vacuum pipe from the control unit and unscrew the adaptor Do not lose the sealing washer from inside the adapter Pul...

Page 7: ...heating element Solder will not wet the tip Tip temperature is too high Tip is badly oxidized and requires cleaning TROUBLESHOOTING SPECIFICATIONS Input Voltage 220 240V 50Hz Power Consumption Desolde...

Page 8: ...e it must be treated as Waste Electrical Electronics Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling o...

Reviews: