5
4
2. Specifications
2.1 Performance data
UNIT
DURAPRO-12
DURAPRO-17
DURAPRO-21
Max Pool volume*
m
3
30 - 60
40 - 75
50-95
Advised Pool volume
m
3
40
50
65
Operating air temperature
°C
-15 ~ 43
Air 27°C / Water 26°C / Humidity 80%
Heating Capacity
kW
2,85 - 12
3,77 - 17
4,6 - 19,5
Btu
9690 - 40800
12818 - 57800
15640 - 66300
Consumed power
kW
0,21 - 2,12
0,3 - 3,02
0,37 - 3,94
COP
13,57 - 5,66
12,57 - 5,63
12,43 - 4,95
Air 15°C / Water 26°C / Humidity 70%
Heating Capacity
kW
2,25 - 9,7
2,92 - 12,4
3,84 - 15,4
Btu
7650 - 32980
9928 - 42160
13056 - 52360
Consumed power
kW
0,32 - 2,08
0,44 - 2,86
0,6 - 3,81
COP
7,03 - 4,66
6,64 - 4,34
6,4 - 4,04
Air 10°C / Water 26°C / Humidity 64%
Heating Capacity
kW
1,88 - 8
2,5 - 10,7
3,38 - 14,4
Btu
6329 - 27200
8500 - 36380
11492 - 48960
Consumed power
kW
0,33 - 1,95
0,45 - 2,64
0,62 - 3,62
COP
5,7 - 4,1
5,56 - 4,05
5,45 - 3,98
Power supply
230V / 50Hz
Current range
A
0,9 - 9,2
1,3 - 13,1
1,6 - 17,1
Compressor quantity
1
1
1
Compressor type
Rotary
Refrigerant
R32
Fan quantity
1
1
1
Fan power input
W
75
120
120
Fan rotary speed
RPM
400 - 800
600 - 750
600 - 750
Fan direction
Horizontal
Horizontal
Horizontal
Noise at 10m
dB(A)
25 - 32
27 - 34
28 - 35
Water connection
mm
50
50
50
Nominal water flow
m
3
/h
4,2
5,3
6,6
Water pressure drop (max)
kPa
4,5
5
6
Unit net dimensions (L*W*H)
mm
1003x396x767
1046x435x768
1161x470x863
Unit shipping dimensions (L*W*H)
mm
1130x460x790
1120x460x780
1200x510x880
Net weight
kg
59
77
82
Shipping weight
kg
69
89
95
* Advised pool volume for an entirely insulated pool, with cover, free from wind and exposed to the sun
In case the pool volume is close to the maximum value, the inverter heatpump will nearly always run at full power
** Advised pool volume for efficient heating
UNIT
DURAPRO-25S
DURAPRO-28TS
Max Pool volume*
m
3
65 - 120
90 - 169
Advised Pool volume
m
3
75
105
Operating air temperature
°C
-15 ~ 43
Air 27°C / Water 26°C / Humidity 80%
Heating Capacity
kW
4,7 - 24,0
7,7 - 28,0
Btu
16036 - 81888
26272 - 95536
Consumed power
kW
0,36 - 4,0
0,59 - 4,7
COP
13,0 - 6,0
13,0 - 6,0
Air 15°C / Water 26°C / Humidity 70%
Heating Capacity
kW
4,4 - 18,5
6,4 - 21,8
Btu
15012 - 63122
21837 - 74382
Consumed power
kW
0,61 - 4,02
0,88 - 4,74
COP
7,20 - 4,60
7,30 - 4,60
Air 10°C / Water 26°C / Humidity 64%
Heating Capacity
kW
5,0 - 15,6
5,7 - 17,8
Btu
17060 - 53227
19448 - 60733
Consumed power
kW
0,82 - 3,91
0,90 - 4,13
COP
6,1 - 4,0
6,3 - 4,3
Power supply
230V / 50Hz
380-400V (3Phase)
current range
A
3,2 - 20,5
1,4 - 8,8
Compressor quantity
1
1
Compressor type
Rotary
Refrigerant
R32
Fan quantity
1
1
Fan power input
W
150
150
Fan rotary speed
RPM
400 - 800
400 - 800
Fan direction
Horizontal
Horizontal
Noise at 10m
dB(A)
26 - 37
28 - 38
Water connection
mm
50
50
Nominal water flow
m
3
/h
10
12
Water pressure drop (max)
kPa
14
17
Unit net dimensions (L*W*H)
mm
1160x490x862
1160x490x862
Unit shipping dimensions (L*W*H)
mm
1210x510x880
1210x510x880
Net weight
kg
92
96
Shipping weight
kg
105
109
* Advised pool volume for an entirely insulated pool, with cover, free from wind and exposed to the sun
In case the pool volume is close to the maximum value, the inverter heatpump will nearly always run at full power
** Advised pool volume for efficient heating