![Duratech Dura Pro 12 Installation Instructions Manual Download Page 19](http://html1.mh-extra.com/html/duratech/dura-pro-12/dura-pro-12_installation-instructions-manual_2541469019.webp)
19
Fault
display
F08
F17
F04
F12
F22
F02
F10
F19
F06
F14
F24
F01
F09
F18
F05
F13
F23
F03
F11
F20
F07
F16
F15
F25
Elimination methods
Check the input voltage measurement
Check and measure the voltage
adjustment
Check the measuring voltage check
frequency conversion board hardware
Check the communication connection
Check and adjust the current
measurement
Check the
communication connection
Check the input voltage measurement
Inspect and replace the sensor
Check and adjust the current
measurement
Check the communication connection
Check and adjust the current
measurement
Recovery after the 150s
Check the input voltage measurement
Check and adjust the current
measurement
Check whether current return wires
connected motor,
Check the communication connection
The compressor over-current
protection
Recovery after the 150s
Check and adjust the current
measurement
Check and adjust the current
measurement
Check the input voltage measurement
Check and adjust the current
measurement
Check whether the chip is damaged
Replace the chip
Protection/fault
Dc voltage is not enough
The input voltage lost phase
Compressor start-up failure
DSP and PFC connect fault
Transducer overheating
alarm
Frequency conversion board
offline
Input voltage is large
Radiator temperature sensor
fault
IPM Input current is large
protection
DSP and MCU connect fault
Input current too large alarm
MOP drive alarm
Input voltage is not enough
IPM sampling electricity
Dc fan fault
DSO and SPPB connect fault
Compressor electricity large
protection
IPM modular protection
Voltage sampling fault
Transducer overheating
protection
Dc voltage is large
Weak magnetic field
protection
IPM overheating protection
EEPROM error alarm
Reason
DC bus voltage<Dc bus over-voltage
protection value
The input voltage lost phase
Lack of phase, step or drive hardware
damage
DSP and PFC connect fault
Transducer temperature is too
high
Frequency conversion board and main
board communication failure
The input voltage is too high, more than
outage protection current RMS
Sensor is short circuit or open
circuit
IPM Input current is large
DSP and MCU connect fault
Input current is too large
MOP drive alarm
The input voltage is low, causing the
input current is high
IPM sampling electricity is fault
Motor current feedback open circuit or
short circuit
DSO and SPPB connect fault
Compressor electricity is large
IPM modular protection
The input voltage sampling fault
The transducer is overheat
DC bus voltage>Dc bus over-voltage
protection value
Compressor magnetic force is not
enough
The IPM module is overheat
MCU error