PROBLEM
POSSIBLE CAUSES
SOLUTION
The unit is not
working
Power failure
Wait for the power to be restored
The power is turned off
Turn on the power
The fuse is burned out
Replace the fuse
The unit’s 3-minute protection has
been activated
Wait three minutes after restarting the
unit
Timer is activated
Turn timer off
NOTE
If your problem persists after performing the checks and diagnostics above, or the error
code remains, turn off your unit immediately and contact an authorized service center.
ERROR CODES
CODE ERROR
E0
Indoor EEPROM malfunction
E1
Communication malfunction between indoor and outdoor unit
E2
Zero-crossing signal detection error
E3
Indoor fan speed malfunction
E4
Ambient temperature sensor (T1) malfunction
E5
Evaporator temperature sensor (T2) malfunction
EC
Refrigerant leakage detection
F0
Current overload protection
F1
Outdoor temperature sensor (T4) malfunction
F2
Outdoor condeser pipe temperature sensor (T3) malfunction
F3
Discharge air temperature sensor (TP) malfunction
F4
Outdoor EEPROM malfunction
F5
Outdoor fan speed malfunction
F6
T2B sensor malfunction (Multi-zone outdoor units only)
P0
IPM malfunction or IGBT current protection
P1
Voltage protection - DC voltage between P&N out of range
P2
High temperature protection of IPM module or compressor
P3
Outdoor temperature too low
P4
Inverter compressor drive error
P6
High/Low pressure protection
(Only Appear on the Unit's Display Panel)