Durasage FRB-2F3 User Manual And Instruction Manual Download Page 13

10

Trouble shooting

Problems

Possible Reasons

Solutions

4

5

6

 

 

1

2

3

Poor display

Controller 
wont turn on

Temperature 
display is not 
working 
correctly

Radio without 
sound

System alarm

7

Stops heating 
after awhile

Bluetooth is 
not paired 
properly

Digital tube quality problem

Digital tube driver IC is
damaged
CPU burned out

The controller’s connection is

loose

Temperature sensor damaged

Check if other devices are 
paired

Bluetooth driver module is 
broken

The screen displays HH and 
alarms

The screen displays E1 and 

alarms

The screen displays EO and 

alarms

Motherboard amplifier is 

broken

Replace the display panel

Replace a new CPU

No power input

Check for power

Reconnect the control computer cable

Replace the temperature sensor

Disconnect the paired device

Check if the Bluetooth 
version is compatible. The 
system supports version 2.0 
or 4.0

Use device with matcing version

Replace the 4-in-1 audio module

Excessive temperature

Sensor short circuit

The system has overload, 

overcurrent protection

Temperature sensor partial 
overheating

First check if there is an open circuit, if no 
open circuit, restart current limit protec

-

tion

Check why the partial area is overheating

Sensor disconnected

Replace the motherboard

Radio module is broken
Speaker cable is broken 
or the speaker is broken

Replace the 4-in-1 audio module

Replace the wire or replace the speaker

Applicable to Controller

Summary of Contents for FRB-2F3

Page 1: ...Wooden Infrared Sauna User Guide and Instruction Manual FRB 2F3 WARNING Read all instructions carefully before using this sauna This product should always be used with care ...

Page 2: ......

Page 3: ...tents Important safety guides 1 Structure of infrared sauna 2 Installation process 3 Installation precautions 4 Control panel operation 5 Control box 7 Maintenance 8 Trouble shooting 9 Customer Support 11 ...

Page 4: ...ure environment 11 Use caution when drinking alcohol 12 Avoid using if you have hemophilia or are prone to bleeding 13 Please consult with your doctor before using if you have health con cerns and or taking prescribed medicine 14 Do not use immediately after intense exercise wait until the body s core temperature returns to normal before use 15 If you feel any discomfort stop using the sauna immed...

Page 5: ...dle 1 2 3 4 Control box Duster cover 5 Temperature sensor Topboard Backboard Heater frame 11 12 Right board 13 14 15 Door glass 10Ventilation 6 8 9 7 Front board Foot rest board Bench front board Bench Bottom board 16 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 15 17 18 19 ...

Page 6: ...Installation process Back board Left board Bench Bench front board Bottom board Right board Top board Front board Foot rest board 3 ...

Page 7: ...Installation precautions Large plate assembly Outer buckle installation method 4 Electrical connection 1 2 Conection cable Connection plug ...

Page 8: ...imes when there is 5 minutes left See the next page for details Audio function See the next page for details Power lock function Press and hold LOCK button for 5S when the indicator light turns on the display is now locked To unlock press and hold LOCK button for 5S indicator light will turn off Timer display Displays timer USB function Touch this key to start USB function Power button Touch this ...

Page 9: ...tion While radio is on press and hold AUDIO button it will search for frequencies automatically The frequency range is 87 5MHZ 108MHZ when search the effective signal frequency it will save it Using the system for the first time you will need to scan for the local channels 4 Press the forth time turn off sound function Light button On the status of system standby press LIGHT button to turn on or tu...

Page 10: ...A LOAD F Main power of sauna room Fuse reset Lamp power output cable 12V output Control panel connecting Antenna USB output Color lamp power output Audio output Temperature sensor connection port 1 2 3 4 5 5 L A M P A B L O A D C L O A D D L O A D E L O A D F L O A D 4 1 2 3 L A M P A L O A D C L O A D D L O A D E L O A D F L O A D B L O A D A C P O W E R L N O C P ...

Page 11: ...acuum cleaner 2 Do not use organic solvents to clean surfaces such as gasoline alcohol etc wipe the sauna surface 3 Do not use sharp objects in sauna cabin to prevent scratching woods Stain on glass 1 Clean the glass with soft materials 2 Stubborn stains can be wiped with a damp cloth then dry with a dry cloth 3 Do not scratch the surface with a sharp object to prevent scratching the glass Transpo...

Page 12: ...t board of the relay is not working The circuit s problems Replace the circuit board 1 There is a plastic bag around remove it 2 Some heater s temperature too high turn off the power supply and replace it 3 Parts on the circuitry are broken Check if junction of the temperature sensor is loose and replace it Check and make sure they are tight Replace with a new one of the same specifications Check i...

Page 13: ...lace the display panel Replace a new CPU No power input Check for power Reconnect the control computer cable Replace the temperature sensor Disconnect the paired device Check if the Bluetooth version is compatible The system supports version 2 0 or 4 0 Use device with matcing version Replace the 4 in 1 audio module Excessive temperature Sensor short circuit The system has overload overcurrent prot...

Page 14: ...isted below the Limited Warranty Period One Year Limited Warranty Period One and a half Year 1 5 from original purchase date All Electronic Durasage Products unless otherwise stated During the Warranty Period Durasage will repair replace at no charge products or parts of a product that proves defective because of improper material or workmanship under normal use and maintenance What does this limi...