4 hours 

place the UPS away from other units at least 20 cm to avoid interference. DO NOT operate the UPS 
where the temperature and humidity is outside the specific limits. (Please check the specs for the 
limitations.) 

2. Charging 

Plug in the AC input cord to the wall outlet. For the best results, 
suggest charging the battery at least 4 hours before initial use. The 
unit charges its battery while connecting to the utility. 

3. Connection of Equipment 

Plug in the loads to output receptacles on the rear panel of the UPS. 
Simply turn on the power switch of UPS unit, then devices 
connected to the UPS will be protected by UPS unit. 

4. Connection of Network 

To surge protect a network connection, connect a network cable from the wall jack outlet to the IN 
jack of the UPS.    Then connect a network cable from the OUT jack of the UPS to the network 
device.   

5. Connection of Communication 

UPS equipped with communication port allows monitoring and controlling from computer screen.   
Connect one end of a communication cable to your PC and the other to the com port at the rear of 
the UPS. 
 
ViewPower is an UPS power management software, allowing users to control and monitor UPS 
straightly from PC monitor.    Insert ViewPower software CD or download ViewPower software from 

http://www.power-software-download.com

 to your hard drive.    Follow on-screen instructions to 

complete the software installation. 
 
After computer is restarted, ViewPower is geared and presents as an orange plug icon located in 
the system tray at the right-bottom corner.

 

 

 

6. Turn On/Off 

 

To  turn  on  the  UPS,  press  power  switch  lightly.    To turn  off  the  UPS,  please  press  power switch 
again. 

7.

 

Green Power Function   

DM615N-650 and DM615N-850 UPS are equipped with Green Power Function.    For saving power 
and protecting battery, the method of deep discharging protection is adopted on inverter mode. 

 

Trouble-shooting

 

Use the table below to solve minor problems.    If any abnormal situations occur that are not listed 

above, please call service technician for assistance. 

Problem 

Possible Cause 

Solutions 

No LED display on 

the front panel. 

Low battery. 

Charge the UPS at least 6 hours. 

Battery fault. 

Replace the battery with the same type of 

battery. 

The UPS is not turned on. 

Press the power switch again to turn on the 

UPS. 

Alarm continuously   

sounds when the   

mains is normal. 

The UPS is overload. 

Remove some loads first. Before reconnecting 

equipment, please verify that the load matches 

the UPS capability specified in the specs. 

When power fails, 

back-up time is 

shortened. 

The UPS is overload. 

Remove some critical load. 

Battery voltage is too low. 

Charge the UPS at least 6 hours. 

Battery defect. It might be due to high 

temperature operation environment, or 

improper operation to battery. 

Replace the battery with the same type of 

battery. 

The mains is normal, 

but LED blinks.. 

Power cord is loose. 

Reconnect the power cord properly. 

 

Specifications

 

Model 

650 

850 

1000 

1500 

2000 

CAPACITY 

650VA/ 

360W 

850VA/ 

480W 

1000VA/ 

600W 

1500VA/ 

900W 

2000VA/ 

1200W 

INPUT

 

Voltage 

110/120 VAC or 220/230/240 VAC 

Voltage Range 

81-145 VAC / 162-290 VAC 

OUTPUT

 

Voltage Regulation 

+/-10% 

Transfer Time 

Typical 2-6 ms, 10 ms max. 

Waveform 

Simulated Sine Wave 

BATTERY

 

Type & Number 

12V/7AHx1 

12V/9AHx1 

12V/7AHx2 

12 V/9 AH x 2 

Charging Time 

4-6 hours recover to 90% capacity 

PHYSICAL

 

Dimension, DxWxH, (mm)   

287x100x142 

350x146x 160 

397x146x205 

Net Weight (kgs) 

4.25 

4.90 

8.0 

11.1 

11.5 

Environment

 

Humidity 

0-90 % RH @ 0-40° C (non-condensing) 

Noise Level 

Less than 40 dB 

MANAGEMENT

 

USB 

Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008 

* Product specifications are subject to change without further notice.

 

 