SONDELTOX
INTERFERRING GASES
CONNECTION
ZEROING / CALIBRATION GAS
GUARANTEE
SONDELTOX
is guaranteed against any manufacturing defect for 1 year
from the date of purchase. The guarantee covers the total repair of the
equipment and will only be valid if the equipment has been installed
by a competent person and following the specifications in this manual.
Negligent use or installation will exempt
DURAN ELECTRONICA
from its
responsibilities for damage caused to property and/or people and from the
fulfilment of the terms of this guarantee.
The guarantee does not cover:
- Installations, periodical checks and maintenance.
- Repairs caused by improper handling, inappropriate use, negligence,
overload, insufficient power supply or neglecting the equipment, voltage
shorts, defective installations and other external causes.
- Repairs or adjustments carried out by personnel not authorised by
DURAN ELECTRÓNICA.
- The equipment transport costs.
DURAN ELECTRÓNICA
reserves the right to carry out improvements or to
include modifications in this manual without prior notice.
For
SONDELTOX
detectors zeroing –except for
SONDELTOX
O
2
- please
proceed as follows:
1- Cover the detector during 15 min.
2.-Place a multimeter at the scale of 200mV, in parallel, with the yellow
and green cable (fig 1).
3- Adjust through the ZERO potentiometer of the detector circuit until a
reading of 40mV (4mA) is reached.
4- Remove the detector plug. With the plug provided and keep it for future
testings.
For
SONDELTOX
O
2
zeroing, adjust the potentiometer until obtaining a
measurement of 178mV, equivalent to 20.9% of O
2
, in a wide and well
ventilated room.
The detectors recalibration with gas must be carried out at our laboratories.
SONDELTOX has been tested with several commonly cross-interferring gases and the results are expressed in the table below (in ppm):
Use 2 x 1 mm
2
shield cable for power supply.
GREEN Cable:
Zeroing (multimeter positive borne)
YELLOW Cable:
Zeroing (multimeter negative borne)
BLACK Cable:
Negative of power supply. 4-20mA Output.
RED Cable:
Positive of power supply. 4-20mA Output.
SONDELTOX
CO is provided with a filter to minimize H2S influence, SO
2
and other interferring gases.
SONDELTOX
CO
H
2
S
SO
2
NO
NO
2
Cl
2
HCl
H
2
Interferring Gases
CO
-
300
/
≤
6
300
/
<3
300
/
0
300
/
0
300
/
0
300
/
<3
300
/
<50
H
2
S
5
/
>1
-
15
/
≈
20
15
/
≈
5
15
/
≈
-3
15
/
≈
1,5
15
/
≈
10
15
/
<3
SO
2
5
/
0
5
/
<1
-
5
/
0
5
/
0
5
/
0
5
/
≈
2
5
/
0
NO
35
/
<3,5
35
/
0
35
/
0
-
35
/
0
35
/
0
35
/
0
35
/
≈
10
NO
2
5
/
0
5
/
≈
-1
5
/
≈
6
100
/
0
-
5
/
≈
5
5
/
0
5
/
0
Cl
2
1
/
0
1
/
≈
0,1
1
/
≈
0.5
1
/
0
1
/
≈
1X
-
1
/
≈
0
1
/
0
H
2
100
/
<60
100
/
<0,2
100
/
0
100
/
0
100
/
0
100
/
0
100
/
0,5
-
HCN
10
/
0
10
/
0
10
/
≈
5
10
/
0
10
/
0
10
/
0
10
/
0
10
/
≈
3
HCl
5
/
0
5
/
0
5
/
0
5
/
<1
5
/
0
5
/
0
-
5
/
0
Ethylene
100
/
<75
100
/
0
100
/
0
100
/
0
100
/
0
100
/
0
100
/
0
100
/
≈
80
(fig 1)
Certificate nº FS82426