SONDELTOX

INTERFERRING GASES

CONNECTION

ZEROING / CALIBRATION GAS

GUARANTEE

SONDELTOX 

is guaranteed against any manufacturing defect for 1 year 

from the date of purchase. The guarantee covers the total repair of the 
equipment and will only be valid if the equipment has been installed 
by a competent person and following the specifications in this manual. 
Negligent use or installation will exempt 

DURAN ELECTRONICA

 from its 

responsibilities for damage caused to property and/or people and from the 
fulfilment of the terms of this guarantee.

The guarantee does not cover: 
- Installations, periodical checks and maintenance.

- Repairs caused by improper handling, inappropriate use, negligence, 
overload, insufficient power supply or neglecting the equipment, voltage 
shorts, defective installations and other external causes.
- Repairs or adjustments carried out by personnel not authorised by 

DURAN ELECTRÓNICA.

- The equipment transport costs.

DURAN ELECTRÓNICA 

reserves the right to carry out improvements or to 

include modifications in this manual without prior notice.

For 

SONDELTOX 

detectors zeroing –except for 

SONDELTOX 

O

- please 

proceed as follows:
 
1- Cover the detector during 15 min. 
2.-Place a multimeter at the scale of 200mV, in parallel, with the yellow 
and green cable (fig 1).

3- Adjust through the ZERO potentiometer of the detector circuit until a 
reading of 40mV (4mA) is reached. 

4- Remove the detector plug. With the plug provided and keep it for future 
testings.

For 

SONDELTOX

 O

zeroing, adjust the potentiometer until obtaining a 

measurement of 178mV, equivalent to 20.9% of O

2

, in a wide and well 

ventilated room.

The detectors recalibration with gas must be carried out at our laboratories.  

SONDELTOX has been tested with several commonly cross-interferring gases and the results are expressed in the table below (in ppm):

Use 2 x 1 mm

2

 shield cable for power supply.

GREEN Cable:

Zeroing (multimeter positive borne)

YELLOW Cable:

Zeroing (multimeter negative borne)

BLACK Cable:

Negative of power supply. 4-20mA Output.

RED Cable:

Positive of power supply. 4-20mA Output.

SONDELTOX 

CO is provided with a filter to minimize H2S influence, SO

2

 and other interferring gases.

SONDELTOX

CO

H

2

S

SO

2

NO

NO

2

Cl

2

HCl

H

2

Interferring Gases

CO

-

300

 / 

6

300

 / 

<3

300

 / 

0

300

 / 

0

300

 / 

0

300

 / 

<3

300

 / 

<50

H

2

S

5

 / 

>1

-

15

 / 

 20

15

 / 

5

15

 / 

 -3

15

 / 

 1,5

15

 / 

 10

15

 / 

<3

SO

2

 / 

0

5

 / 

<1

-

5

 / 

0

5

 / 

0

5

 / 

0

5

 / 

 2

5

 / 

0

NO

35

 / 

<3,5

35

 / 

0

35

 / 

0

-

35

 / 

0

35

 / 

0

35

 / 

0

35

 / 

 10

NO

2

5

 / 

0

5

 / 

 -1

5

 /

 

 6

100

0

-

5

 /

 

5

5

 /

 0

5

 /

 0

Cl

2

1

 / 

0

1

 / 

 0,1

1

 / 

 0.5

1

 / 

0

1

 /

 

1X

-

1

 / 

 0

1

 / 

0

H

2

100

 / 

<60

100

 / 

<0,2

100

 / 

0

100

 / 

0

100

 / 

0

100

 / 

0

100

 / 

0,5

-

HCN

10

 / 

0

10

 / 

0

10

 / 

 5

10

 / 

0

10

 / 

0

10

 / 

0

10

 / 

0

10

 / 

 3

HCl

5

 / 

0

5

 / 

0

5

 / 

0

5

 / 

<1

5

 / 

0

5

 / 

0

-

5

 / 

0

Ethylene

100

 / 

<75

100

 / 

0

100

 / 

0

100

 / 

0

100

 / 

0

100

 / 

0

100

 / 

0

100

 / 

 80

(fig 1)

Certificate nº FS82426