Installation and Usage

• 

This kind of socket can be reconnected. Before opening the socket box, make sure the power supply 

is halted.

• 

When changing the connecting wire, please use the following type of wire: H07RN-F 3G 1.5 mm². The 

length of the wire is at least 1.4 meters.

• 

Please make sure to correctly connect the green/yellow grounding safety lead wire to the connecting 

location with grounding safety lead wire mark.

• 

The wires must be led to the connection terminal in the shortest possible way Grounding safety lead 

wire should be 8 mm longer than required.

• 

The lead wire must be connected firmly to the binding post and all the lead wires should be inside the 

binding post.

• 

The spray-proof rubber packing and the sealing ring must be mounted in place precisely. Fasten the 

screws properly.

• 

Use the supplied remote control to switch the sockets on/off separately. With appropriate batteries 

inserted, the RC automatically connects to the corresponding socket.

• 

When exchanging the battery, be sure to maintain the correct polarity as indicated on the inside of 

the battery compartment. Exlusively use batteries of the equal type.

Technical Data

Article #.

10028985

10028986

10028991

10028987

10028988

10028992

10028989

10028990

10028993

Supply Line

1.5m

3.0m

5.0m

Voltage

250V AC,  ~50Hz

250V AC,  ~50Hz

250V AC,  ~50Hz

Maximum Load

10A, 2500W

10A, 2500W

10A, 2500W

IP Protection Class

IP44

IP44

IP44

Radio Frequency (RC)

433.92MHz

433.92MHz

433.92MHz

Range (RC)

70m (max.)

70m (max.)

70m (max.)

Battery Type (RC)

8LR932  1811A  23A  (ca.28,5mm×Ø10,3mm)  12 V

Scope of Delivery

Device, remote control, instruction manual