EXTENSION CORDS: For best performance, it is recommended to connect the AC 
transformer power cord directly to a grounded GFCI outlet.  The use of extension cords is 
NOT recommended.  

Do not use the power cord or discharge hose to carry or handle the pump. Doing so may 
cause  damage  to  the  power  cord  or  discharge  hose.    Use  the  carrying  handle  supplied 
with the pump. 

Always use a grounded outlet to attach the plug.  A three-prong mating type receptacle is 
needed for safe use.  This should be in accordance with the National Electric Code and any 
additional codes or laws required by your local government.   

It  is  strongly  recommended  to  use  a  ground  fault  interrupt  device  on  any  electrical 
appliance,  including  this  pump,  when  used  in  a  wet  or  moist  environment.    This  GFCI 
(ground fault  circuit  interrupter)  should  be  listed  by Underwriters Laboratories (UL).   This 
is  required  by  many  local  codes  and  enforcement  agencies.    It  is  strongly  recommended 
by A.Y. McDonald as it provides a much safer installation and will greatly reduce possible 
injury from electrical shock. 

Your pump has thermal over-load protection built in.  It is not recommended for pumping 
liquids over 120°F.  The thermal overload protector will automatically shut down the pump 
in an overheat situation.  It will then reset itself once the pump cools down. The pump will 
then work again.  This overload is designed as a safety device and it will fail after repeated 
use.  Normal operation is for fluids between 32°F & 120°F.  

DO NOT RUN THE PUMPS DRY. The pumps depends on water for cooling and lubrication.  
Operating the pumps without water may cause the motor to overheat or cause damage to 
parts of the pump.  It may also shorten the life of your pumps. 

EXTENSION CORDS: For best performance, it is recommended to connect the power cord 
directly to the grounded GFCI outlet.  If the use of an extension cord is necessary, always 
use a grounded waterproof type cord.  Never use longer than a 25-ft. cord that is lighter 
than 14/3 gauge.  

A qualified electrician must perform all wiring. 

Summary of Contents for 5030CVSPBUSS

Page 1: ...12 www aymcdonald com A Y McDonald BBU Manual Revised 8 13 3210 479 Rev A INSTALLATION OPERATION MANUAL PRE ASSEMBLED PRIMARY BATTERY BACK UP SUMP PUMP SYSTEM 5030CVSPBUSS 5033CVSPBUSS ...

Page 2: ...unded grounding type receptacle This pump has been manufactured with your needs in mind Properly installed in the right application your new A Y McDonald pump will give you years of carefree performance Keep all electrical connections away from wet and moist environments Wet connections can cause electrical shock resulting in personal injury Do not use this unit to pump chemicals flammable liquids...

Page 3: ...ncies It is strongly recommended by A Y McDonald as it provides a much safer installation and will greatly reduce possible injury from electrical shock Your pump has thermal over load protection built in It is not recommended for pumping liquids over 120 F The thermal overload protector will automatically shut down the pump in an overheat situation It will then reset itself once the pump cools dow...

Page 4: ...lowing actions 1 Take immediate action for personal safety as outlined in the CO detector manual 2 Contact the appropriate utility agency to determine if the CO is coming from your furnace water heater or other appliance that uses natural gas If it s determined that a charging battery is causing the CO detector to activate contact the manufacturer for recommendations on how to alleviate the proble...

Page 5: ... a threaded post terminal built in NOTE The provided battery terminals are labeled positive and negative Make sure the terminals are connected to the proper terminal on the battery Place the battery in the battery box 2 Connect the battery lead wires from the control panel to the corresponding terminals on the battery Connect the red positive lead to the positive battery terminal and tighten the w...

Page 6: ...Defective or missing check valve Install or replace check valve Pump runs but moves little or no water Low or discharged battery Fully charge battery Obstruction in pipe Clear obstruction Discharge pipe height length exceeds the capacity of the pump Check performance section for capacity of this pump Defective check valve Replace Check Valve if necessary 7 120 VOLT AC PRIMARY PUMP TROUBLESHOOTING ...

Reviews: