INSTALLATION (New Pump) 

1.

 

Set your new pump in the bottom of the sump basin off to one side. The pump should be 
placed on a solid foundation. Do not place the pump directly on the ground or on sandy 
or rocky surfaces. Sand and small stones may clog or cause damage to your pump.   

 
2.

 

Make  sure  the  float  switch  will  swing  freely  from  the  bottom  to  top  without  coming  in 

contact with the side of the sump basin.  Contact with the side of the sump basin may 
cause the switch to malfunction. See figure below. 

 
 
 

 
 
 
 
 
 

 
 
 
 
 

 
 
 

3.

 

It is highly recommended to install a full flow, swing type check valve (not included) 
as close to the discharge outlet on the pump as possible.  A new check valve will 

greatly increase the life of your pump. The check valve should be the same size as 
the pump discharge. 

 

4.

 

Connect  the  pump  and  check  valve  together  using  schedule  40  PVC  pipe  and 
fittings. You can also use DWV or ABS pipe, as this is not a pressure installation.  
Corrugated drain hose is intended for temporary use and should not be used in a 

permanent installation. Although there are many types of pipe that work adequately 
for this installation, PVC is recommended. 

 

5.

 

Test your installation after you have completed setting up the pump. Plug the cord 
from the pump into the piggyback plug of the float switch, then plug that into your 
grounded outlet. The pump should not run at this point. If the pump runs, the switch 
is stuck in the upright position or the pump is plugged directly into the outlet and not 
through the piggyback switch plug. Fill the sump basin with water using buckets or a 

hose.  When  the  switch  floats  to  the  upright  position,  the  pump  will  turn  on.  The 
switch will turn off the pump when it reaches the down position. You may adjust the 
switch  to  meet  your  particular  needs.  Remember  the  switch  must  swing  freely 
without touching the sides of the sump basin. NOTE: The cut out (turn off) setting is 
the only adjustment available on vertical type switches. 

 

TROUBLESHOOTING 

PROBLEM 

POSSIBLE CAUSES 

HOW TO CORRECT 

If the pump does not 
start or run 

 

Pump is not plugged in, switch or 
breaker is off 

 

Plug pump in or turn on 
switch/breaker 

 

Check for blown fuses or tripped circuit 
breakers or tripped GFCI outlets 

 

Replace fuse, reset breaker, reset 
GFCI outlet 

 

Float switch is defective 

 

Check and replace if necessary 

 

Motor thermal protector tripped 

 

Allow pump to cool.  Pump will reset 

 

Float switch is stuck or obstructed 

 

Remove obstruction or position pump 
so it will not become stuck 

The pump starts and 
stops too often 

 

Backflow of water from discharge 
hose/pipe 

 

Install or replace check valve 

 

Float switch is defective 

 

Replace float switch 

If  the  pump  runs  but 
moves little or no water

 

 

Clogged intake screen 

 

Clean or replace screen 

 

Clogged discharge hose/pipe 

 

Remove clog 

 

Frozen discharge hose/pipe 

 

Allow hose/pipe to thaw 

 

Pump is air locked 

 

Clean out airlock hole with a paper 
clip or pipe cleaner 

 

Low line voltage 

 

Check wire size and increase if 
necessary 

 

Check valve is stuck in the closed 
position 

 

Inspect, repair or replace if necessary 

 

Check valve is installed backwards 

 

Make sure check valve is installed in 
the correct direction of flow 

 

Worn, damaged or clogged pump parts 

 

Inspect for wear, damage or clog and 
clean or replace if necessary 

 

Discharge head exceeds pump 
capacity 

 

If pumping height is over 25’, the 
pump will not move water.  See 
performance chart 

Pump does not 
shut off 

 

Float switch is obstructed or stuck 

 

Remove obstruction 

 

Defective Float Switch 

 

Replace switch 

 
 

 

 

Vertical Switch Installations 

Wide Angle Switch Installations 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.

 

Grounded Outlet.  A GFCI outlet 
is strongly recommended. 

B.

 

Full-flow swing type check valve 

C.

 

Discharge Pipe 

D.

 

 Sump basin.  Min. 14” diameter 

E.

 

Position pump so the float switch 
operates freely without touching 
the sides of the basin. 

 

 

Summary of Contents for 5025PTSP

Page 1: ... INSTALLATION AND OPERATION INSTRUCTIONS FOR SUBMERSIBLE SUMP PUMPS Models 5025PTSP 5025PVSP 5030CVSP 5030CTSP 5030CUSP 5030CUSP25 5033PVSP 5033CUSP 5033CUSP25 5033CVSP 5050CVSP 5050CUSP25 AY McDonald Sump Manual Revised 3 11 3210 418 ...

Page 2: ...ted only to a properly grounded grounding type receptacle WARNING Do not use the power cord or discharge hose to carry or handle the pump Doing so may cause damage to the power cord or discharge hose Use the carrying handle supplied with the pump WARNING Always use a grounded outlet A three prong mating type receptacle is needed for safe use This should be in accordance with the National Electric ...

Page 3: ...overheat or cause damage to parts of the pump It may also shorten the life of your pump NOTICE EXTENSION CORDS For best performance it is recommended to connect the power cord directly to the grounded GFCI outlet If the use of an extension cord is necessary always use a grounded waterproof type cord Never use longer than a 25 ft cord that is lighter than 14 3 gauge DANGER Keep all electrical conne...

Page 4: ...ust swing freely without touching the sides of the sump basin NOTE The cut out turn off setting is the only adjustment available on vertical type switches TROUBLESHOOTING PROBLEM POSSIBLE CAUSES HOW TO CORRECT If the pump does not start or run Pump is not plugged in switch or breaker is off Plug pump in or turn on switch breaker Check for blown fuses or tripped circuit breakers or tripped GFCI out...

Reviews: