www.duralloy.net.au
|
1300 369 456
8
171
& 191
MULTIMIG
OWNER’S MANUAL
5.1.5 Controls for MIG welding
5.1.5.1 Gas selection: CO2--ordinary CO2 gas; MIX--20% CO2
80% argon; FLUX-- flux cored
5.1.5.2 Function selection: 2T in MIG mode/4T in MIG mode;
VRD in MMA mode
5.1.5.3 Welding mode selection: MIG welding mode; TIG
welding mode; MMA welding mode
5.1.5.4 Voltage meter: in MIG mode it shows setting voltage
and welding voltage; in other modes no voltage will be
showed.
Warning! - Disconnect the power supply when the Alarm light
flash.
5.1.5.5 Current meter: in MIG mode it shows wire feed speed,
welding current, inductance; in MMA mode it shows current,
hot start current, arc force current.
5.1.5.6 Wire diameter selection: in Synergy mode, select the
wire diameter, press the 9 adjustment knob, the voltage can
be adjusted by ±1V; in Separate mode, welding current and
welding voltage can be adjusted separately--press the button
one time to select voltage or current separate adjustment;
This button cannot work in MMA or TIG mode.
5.1.5.7 Gas check: gas check function, the button cannot work
in MMA or TIG mode.
5.1.5.8 Wire check: wire fast feed button--short press this
button and
5.1.5.9 Adjustment knob: In MIG mode-- voltage adjustment,
inductance adjustment, wire feed speed adjustment, current
adjustment; In MMA mode -- inductance adjustment, hot start
current adjustment; In TIG mode--current adjustment.
5.1.5.10 Mode selection: Hot start function, Arc force function,
Inductance selection (Hot start function, the voltage meter
shows HOL; Arc force, the voltage meter shows FOГ)
Note
: this MIG welding machine MIG welding can be both
synergic and separate, select the wire feed speed the voltage
parameter will be matched automatically.Please select the
wire diameter according to the wire you use. Voltage refine
initialization value is 0, refine the voltage by ±1V according to
different kinds of gas. In synergy mode, the base gas is CO2, to
lower the voltage by 2-3V for mix gas. Inductance initialization
value is 0, adjust range ±10.
Note
: for flux cored wire, connect the Polarity conversion line to
Negative (-) Welding Output Terminal, connect the earth clamp to
Positive (+) Welding Output Terminal; For ordinary wire, connect
the Polarity conversion line to Positive (+) Welding Output Terminal,
connect the earth clamp to Negative (-) Welding Output Terminal
5
1
2
3
4
6
7
8
9
10