![DURAG D-R 290 Operating Manual Download Page 149](http://html.mh-extra.com/html/durag/d-r-290/d-r-290_operating-manual_2541137149.webp)
7 | Checking / setting parameters with D‑ESI 100
D-R 290
149
Temperature compensation
Temperature and pressure compensation using the device
parameters
The Dust and Opacity Monitor D‑R 290 can covert a calculated dust concentration into
a dust concentration per standard cubic metre.
For this the dust concentration determined in mg/m
3
is converted to the standard sta
tus at 0°C according to the following formula:
C
(standard)
=
Temperature of the gas being me 273.15°C
Standard tempe 273.15°C
×
Media pressure
1013.25 hPa
(measurement)
C
The display of the calculated value based on a standard cubic metre is performed by
selecting the type code 0x0052 for one of the four output channels. (see also section
The determination of the media conditions is performed either
●
by describing the media conditions by D−ESI 100, D−ISC 100 or Modbus.
Setting path:
Device (D‑R 290 ) > >
Common parameters
>
D‑R 290
Setting variables
>
Media conditions
●
by using a D−ISC 100 analogue input module and the "Media conditions" software
module in the D−ISC 100.
●
in a special variant of the D‑R 290 via the optional 4−20 mA temperature input
(see section
7.7.10.2 Temperature compensation via an external temperature trans
Temperature compensation via an external temperature
transmitter (special variant)
The necessary determination of the temperature of the gas being measured is per
formed by means of an additional temperature measurement input (4-pin plug connec
tion) at the measuring head (
The parameter
Common Parameters > Setting variables > Media conditions >
Media temperature
for the standardisation described above is meaningless for this device variant.
This input is arranged as a 4..20 mA interface. Suitable temperature transmitters
(transducers) with 4..20 mA output are available as accessories.
The temperature measurement range be selected as any of
●
0..200°C (32..392°F),
●
0..400°C (32..752°F) and
●
0..1000°C (32..1832°F)
and should correspond to the temperature of the gas being measured.
7.7.10
7.7.10.1
7.7.10.2
Fig. 7.23: Temperature
transmitter
Summary of Contents for D-R 290
Page 12: ...12 D R 290 ...
Page 18: ...1 General 18 D R 290 ...
Page 20: ...20 D R 290 ...
Page 28: ...2 Safety 28 D R 290 ...
Page 30: ...30 D R 290 ...
Page 38: ...3 Delivery 38 D R 290 ...
Page 40: ...40 D R 290 ...
Page 60: ...4 Product description 60 D R 290 ...
Page 106: ...106 D R 290 ...
Page 152: ...152 D R 290 ...
Page 174: ...8 Maintenance 174 D R 290 ...
Page 176: ...176 D R 290 ...
Page 178: ...9 Appendix 178 D R 290 Fig 9 2 Measurement point questionnaire 2 ...
Page 194: ...9 Appendix 194 D R 290 ...
Page 200: ...11 Index 200 D R 290 ...
Page 202: ...GmbH Kollaustraße 105 22453 Hamburg Germany www durag com ...