1
LPB-‐15
Desktop Power Supply
Owners Guide
(These instructions are intended for use by a technician familiar with electronic products)
•
Universal input 88~264 VAC
•
Short circuit / over load / over temperature protections
•
Built-‐in EMI filter
•
Front panel DC output indicator
•
Internal battery automatically recharges when AC power is
restored
•
Compatible with all LPH Hoods for custom mobile radio
mounting
•
3 year warranty
DESCRIPTION
Duracomm’s LPB-15 power supply is pre-set to convert 90 to 264 volt 50/60 Hz AC power to low noise and ripple 13.8 volt DC
power. The AC input is auto-ranging and can be used without any changes. The power supply also contains a built-in, replaceable
sealed lead acid battery that automatically takes over should AC power be disrupted. The DC output operating voltage from the internal
battery and AC charger circuitry is delivered to the red and black jacks located on the rear panel. The power supply DC output is
protected against inadvertent shorts and overloads by a thermal circuit breaker.
SPECIFICATIONS
Operational DC Voltage ...................................................................................................................................................13.8 VDC, nominal
Maximum Current, continuous ...................................................................................................................... 14 Amps Max / 12 Amps Cont.
AC Input voltage range .............................................................................................................................................................. 90-264 VAC
AC current.........................................................................................................................................2.2 Amps @ 115V / 1.2 Amps @ 230V
Max inrush current, single cycle ................................................................................. Cold start, 40 Amps / 115 Volts; 70 Amps/ 230 Volts
Overload Protection (operates).........................................................................................................................................DC circuit Breaker
Ripple and noise ......................................................................................................................... 100 mV P-P, or less, built-in EMI Filtering
Internal Battery ............................................................................................................................................ rechargeable, sealed lead acid
...............................................................................................................................12 VDC / 7 Hrs, Powersonic PS-R1270F1 or equivalent
Working Temperature range ..................................................................................................................................... -4 - 140 F (-20 - +60 C)
Storage Temperature.............................................................................................................................................. -40 - 185 F (-40 - +85 C)
Size .........................................................................................................................................................3.75H x 7W x 10D inches, nominal
Weight...................................................................................................................................................................................7.75 lb, nominal