CONNECTING TO THE HE1U-5012-MU VIA THE INTERNET 

Prerequisites 

System

 

administrators

 

must

 

decide

 

whether

 

the

 

HE1U

5012

MU

 

will

 

operate

 

on

 

the

 

network

 

with

 

DHCP

 

or

 

a

 

fixed

 

IP

 

address.

 

The

 

factory

set

 

HE1U

5012

MU

 

will

 

have

 

these

 

static

 

addresses:

 

IP

 

address:

 

192.168.100.220,

 

gateway

 

address:

 

192.168.100.1,

 

netmask:

 

255.255.255.0,

 

and

 

DNS

 

address:

 

192.168.100.1

.

 

If

 

you

 

configure

 

it

 

to

 

use

 

DHCP,

 

the

 

HE1U

5012

MU

 

will

 

request

 

an

 

available

 

IP

 

address

 

on

 

your

 

network.

 

You

 

will

 

need

 

to

 

determine

 

what

 

address

 

it

 

has

 

been

 

given.

 

If

 

DHCP

 

is

 

not

 

used,

 

system

 

administrators

 

must

 

also

 

choose

 

an

 

unused

 

IP

 

address,

 

and

 

other

 

network

 

settings

 

to

 

use

 

in

 

the

 

Network

 

Setup

 

screen.

 

System

 

administrators

 

will

 

also

 

need

 

to

 

choose

 

an

 

email

 

service

 

and

 

address

 

to

 

use

 

for

 

notifications,

 

if

 

needed.

 

These

 

will

 

be

 

used

 

in

 

the

 

Email

 

Setup

 

Screen.

 

DETERMINING THE IP ADDRESS OF THE HE1U-5012-MU 

Power

 

up

 

the

 

HE1U

5012

MU

 

then

 

connect

 

the

 

HE1U

5012

MU

 

to

 

the

 

network

 

with

 

an

 

Ethernet

 

cable.

 

Using DHCP 

You

 

will

 

need

 

to

 

get

 

the

 

IP

 

address

 

in

 

one

 

of

 

two

 

ways.

 

You

 

can

 

get

 

the

 

IP

 

address

 

from

 

the

 

DHCP

 

server’s

 

client

 

list,

 

or

 

you

 

can

 

use

 

a

 

PC

 

on

 

the

 

same

 

network

 

to

 

scan

 

for

 

the

 

new

 

IP

 

address

 

by

 

using

 

a

 

software

 

tool

 

such

 

as

 

Angry

 

IP

 

Scanner.

 

In

 

Angry

 

IP

 

Scanner,

 

you

 

should

 

add

 

the

 

MAC

 

address

 

“Fetcher”

 

under

 

“Tools

 

>

 

Fetchers”.

 

The

 

DuraComm

 

MAC

 

addresses

 

all

 

start

 

with

 

a

 

base

 

address

 

of

 

70

B3

D5

6B

3.

 

Write

 

down

 

the

 

IP

 

address

 

of

 

the

 

HE1U

5012

MU,

 

then

 

proceed

 

to

 

the

 

section

 

in

 

this

 

manual

 

named

 

Open

 

a

 

Web

 

Connection

 

to

 

the

 

HE1U

5012

MU

”.

 

Using Static HE1U-5012-MU IP and Network Configuration 

If

 

your

 

network

 

is

 

not

 

set

 

up

 

for

 

DHCP,

 

you

 

will

 

need

 

to

 

manually

 

configure

 

the

 

settings

 

to

 

match

 

the

 

network

 

it

 

will

 

be

 

used

 

on.

 

Before

 

you

 

can

 

do

 

that,

 

you

 

will

 

need

 

to

 

configure

 

a

 

computer

 

to

 

talk

 

to

 

the

 

HE1U

5012

MU

 

at

 

the

 

default

 

configuration

 

settings

 

shown

 

above.

 

We

 

will

 

use

 

Windows

 

7

 

as

 

an

 

example.

 

Other

 

operating

 

systems

 

will

 

vary,

 

but

 

the

 

overall

 

concept

 

is

 

the

 

same.

 

1.

 

Disconnect

 

your

 

PC

 

from

 

all

 

networks.

 

2.

 

Connect

 

it

 

directly

 

to

 

the

  

with

 

an

 

Ethernet

 

cable

 

(You

 

may

 

need

 

to

 

use

 

an

 

Ethernet

 

crossover

 

cable

 

if

 

the

 

PC

 

does

 

not

 

automatically

 

detect

 

this

 

configuration).

 

3.

 

Open

 

the

 

control

 

panel

 

on

 

your

 

PC

 

and

 

select

 

“View

 

Network

 

Status

 

and

 

Tasks”

 

4.

 

Click

 

on

 

“Change

 

Adapter

 

Settings”

 

on

 

the

 

left

 

side

 

of

 

the

 

screen.

 

5.

 

Right

 

click

 

on

 

“Local

 

Area

 

Connection”

 

and

 

click

 

on

 

“Properties”

 

6.

 

Click

 

on

 

“Internet

 

Protocol

 

Version

 

4

 

(TCP/IPv4)”

 

to

 

highlight

 

it,

 

then

 

click

 

the

 

“Properties”

 

button.

 

7.

 

Before

 

you

 

make

 

any

 

changes,

 

record

 

the

 

existing

 

settings

,

 

so

 

that

 

you

 

can

 

change

 

them

 

back

 

when

 

you

 

are

 

finished

 

setting

 

up

 

the

 

HE1U

5012

MU.

 

8.

 

Enable

 

“Use

 

The

 

Following

 

IP

 

Address”

 

9.

 

Now

 

enter

 

192.168.100.221

 

for

 

the

 

IP

 

address.

 

10.

 

Enter

 

255.255.255.0

 

Subnet

 

mask

  

11.

 

Click

 

OK

 

to

 

save

 

the

 

network

 

configuration.

 

12.

 

Jump

 

to

 

the

 

section

 

in

 

this

 

owners

 

guide

 

named

 

“Open

 

a

 

Web

 

Connection

 

to

 

the

 

HE1U

5012

MU”

 

to

 

log

 

in

 

and

 

enter

 

the

 

final

 

network

 

settings

 

for

 

the

 

HE1U

5012

MU.

 

 

 

 

Summary of Contents for HE1U-5012-MU

Page 1: ...um Power continuous 750 Watts Maximum Ripple and Noise 150 mV p p max Input Voltage Switch Selectable 110 or 220 VAC Input Frequency Range 47 63 Hz Maximum AC Current 8 2 Amps 115 VAC 3 9 Amps 230 VAC...

Page 2: ...d or SNMP Logging Rate 1 minute resolution 1 minute to 1 hour Log Download Format Comma Separated Values CSV File SNMP MIB File Download from Device Setup Page 5V Supply Maximum Current 300 mAmps INST...

Page 3: ...oltage of 60 VDC for the revision 2 monitoring hardware included with the HE1U 5012 MU The Alarm Input Ain is referenced to G and is a LED in series with a 220 Ohm resistor internally and can withstan...

Page 4: ...dress of 70 B3 D5 6B 3 Write down the IP address of the HE1U 5012 MU then proceed to the section in this manual named Open a Web Connection to the HE1U 5012 MU Using Static HE1U 5012 MU IP and Network...

Page 5: ...fox internet Explorer etc and enter the IP address of the power supply on your network into the URL box on the browser see the screenshot below If you are unable to connect to the device with the brow...

Page 6: ...ogin Enter the user name and password Factory default username and password are as follows Admin Users have full control of the device Username admin cannot be changed Password admin Control users hav...

Page 7: ...7 of 20 December 18 2015 NETWORK SETUP...

Page 8: ...arch for training material online under SNMP Traps MIB Browsers and SNMP Monitoring The MIB file for the HE1U 5012 MU can be downloaded from the HE1U 5012 MU after you connect to it with your browser...

Page 9: ...9 of 20 December 18 2015 EMAIL SETUP Email Setup Enter the required email setup parameters given to you by your System Administrator You can also send a test email from this screen...

Page 10: ...10 of 20 December 18 2015 DEVICE SETUP...

Page 11: ...d data so that the source of the card can be identified after it removed from the HE1U 5012 MU SNMP MIB File Download The SNMP MIB File can be downloaded from this page Date and Time Settings Configur...

Page 12: ...12 of 20 December 18 2015 SENSOR SETUP...

Page 13: ...g alarms are set up in the Alarm Setup screen See the Alarm Setup section for more information In the HE1U 5012 MU the Digital Output 1 is an alarm output and Digital Output 2 controls the ON OFF stat...

Page 14: ...14 of 20 December 18 2015 ALARM SETUP...

Page 15: ...screen above Firmware 2 0 includes additional settings for alarms This screen is where thresholds are set to define alarm conditions for the analog channels You can choose to set an email notificatio...

Page 16: ...ld be taken when changing any of these settings NOTE To hard reset your device back to factory settings press the red button on the HE1U 5012 MU PCB and hold it for more than 30 seconds You will need...

Page 17: ...cember 18 2015 REMOTE MONITORING AND CONTROL STATUS PAGE Status screen This screen shows the status of all analog and digital inputs A user can also download the Log file from this page AC Voltage is...

Page 18: ...ile devices Just use the same IP address and add m for example 192 168 100 220 m HE1U 5012 MU MAINTENANCE Battery The battery on the HE1U 5012 MU is used to back up the real time clock for logging pur...

Page 19: ...Copper ferrules prevent the current transfer from being influenced by dissimilar metals and remove the risk of corrosion Always use the correct tool to crimp the ferrule RECOMMENDED COPPER WIRE SIZE...

Page 20: ...d prior to inclusion of such changes DuraComm requires any product needing in or out of warranty service to be returned to DuraComm All requests for warranty service must be accompanied by proof of pu...

Reviews: