Problem: The engine being jumpstarted will not start.

Possible Cause

Solution

Duracell

®

 Powerpack Pro battery is not fully 

charged.

Recharge the Duracell

®

Powerpack Pro battery.

The engine condition is poor.

Have the engine serviced.  

The engine start capacity exceeds the 
Duracell

®

 hPowerpack Pro jump-start 

capability. 

Use a higher power Duracell

®

 

Powerpack Pro.

Problem: The jump-start clamps measure zero volts.

Jump-start power switch is OFF.

Turn the jump-start power switch ON.

Duracell

®

 Powerpack Pro battery needs to be 

recharged.

Recharge the battery.

P

roblem: The compressor runs, but won’t infl ate.

The valve connector may not be securely 
placed on the valve stem.

Make sure the valve connector is 
securely placed on the valve stem 
before closing the thumb latch.

The item being infl ated may have a leak.

Make sure the item being infl ated 
doesn’t have a leak.Check the 
compressor hose for any breaks or 
leaks.

Problem: The compressor runs slowly.

The compressor may have overheated from 
excessive use.

Turn off the compressor and let it cool 
down.

Battery voltage is too low.

Check the condition of the internal 
battery. The battery may need to be 
recharged or replaced.

13. User reference: Tire inflation

The information in the table below is for reference only. For precise 
pressure specifi cations, refer to the information supplied with the item to 
be infl ated.

Type of tire

Typical pressure 
specifi cations (PSI)

Automotive tires

520-13

26

A-78-14

26

E78-14      

30

H-78-14

24

HR-78-15 

28

Bicycle tires

27 x 1 ¼

85

20 x 1 ½

40

Other Infl atables

Football

13

Basketball

9

Volleyball

5

Lawn tractor tire 

22

15. Warranty and return information

Quality guarantee

Battery-Biz guarantees the Duracell

®

 Powerpack Pro to be free of defects due 

to faulty materials or workmanship. This Duracell

®

 Powerpack Pro carries a 

2-year limited warranty from the date of purchase.

If found to be defective, this Duracell

®

 Powerpack Pro will be replaced without 

charge when returned to Battery-Biz. This guarantee does not apply to damage 
from misuse or abuse beyond normal usage. This guarantee gives you specifi c 
legal rights, and you may also have other rights which vary from state to state. 
Should any device be damaged by the Duracell

®

 Powerpack Pro due to defects 

in the product arising from faulty materials or workmanship, Battery-Biz will 
repair or replace (at our option) the Duracell

®

 Powerpack Pro, provided both 

device and product usage instructions have been followed.

 

Send device with the Duracell

®

 Powerpack Pro to:

 

Battery-Biz Inc.

 

1380 Flynn Road, Camarillo, CA 93012

 

Attention: Duracell Product Returns

If you would like additional information on Duracell products call 
1-800-842-2127.

Contacting customer support

If you experience any problems or have any questions regarding your 
Duracell

®

 Powerpack Pro, free technical support is available. Prior to calling, 

please review the technical support tips below.Call from a phone where you 
have access to your device.

Be prepared to provide the following information:
• 

Name, address and telephone number

• 

Name of the DURACELL

®

 product

• 

Make and model of your device

• 

Symptoms of the problem(s) and what led to them

Technical Support is available by telephone:
• 

U.S. and Canada (800) 842- 2127

• 

Outside of the US/Canada: (805) 437-7765

Written inquires should be directed to:
Battery-Biz Inc.
DURACELL Product Inquiry
1380 Flynn Road, Camarillo, CA 93012, USA

Two year limited warranty

The Duracell

®

 Powerpack Pro carries a limited warranty against defects in 

material and workmanship under normal use and service for two years from 
the original date of purchase. The battery inside the product carries a limited 
one year warranty, from the date of purchase, against defects in material 
and workmanship under normal use and service. Battery-Biz, at its option, 
shall repair or replace the defective unit covered by this warranty. Please 
retain the dated sales receipt as evidence of the date of purchase as it will be 
required for any warranty service. In order to keep the warranty in effect, the 
product must have been handled and used as described in the instructions 
accompanying this warranty. This warranty does not cover any damage due 
to accident, misuse, abuse or negligence. If maintained properly the Duracell 
Powerpack Pro will provide years of dependable service. 

12. Troubleshooting

Below are some common problems that can occur with the Powerpack.If 
you cannnot solve your problem, contact your dealer or Duracell Customer 
Service at (800) 842-2127.

Problem: AC appliance will not operate.

Possible Cause

Solution

AC appliance rated more than 300 W 
(Powerpack Pro 1000) or 600 W (Powerpack 
Pro 1300): the safety overload has tripped.

Use an AC appliance with a power rating 
less than 300 W.

AC appliance is rated less than 300 W 
(Powerpack Pro 1000) or 600 W (Powerpack 
Pro 1300): high starting surge has tripped 
the safety overload.

AC appliance may exceed the Duracell

®

 

Powerpack Pro’s surge capability. Use an 
AC appliance with a starting surge within 
the Duracell

®

 Powerpack surge rating.

Battery has discharged to 10.5 V.

Turn OFF the AC Power ON/OFF switch 
and recharge the Duracell

®

 Powerpack.

Duracell

®

 Powerpack Pro has overheated 

due to poor ventilation or excessively warm 
environmental conditions.

Turn the AC Power ON/OFF switch OFF 
and allow the Duracell

®

 Powerpack Pro 

to cool for 15 minutes or more. Clear 
blocked openings or remove objects 
covering the unit, then restart the 
Duracell

®

 Powerpack and move it to a 

cooler environment.

Problem: Overload shutdown.

Possible Cause

Solution

Appliance power
requirements exceed
the capability of the
Duracell

®

 Powerpack Pro.

Unplug the appliance and confi rm that 
the appliance’s power requirement is 
300 W (Powerpack Pro 1000) / 600 W 
(Powerpack Pro 1300) or less before 
attempting to restart the appliance.

Problem: Measured AC output voltage is too low

.

Possible Cause

Solution

Using an average-reading AC voltmeter to 
read output voltage.

The modifi ed sine wave output of the 
Duracell

®

 Powerpack requires a true 

RMS reading meter, such as the Fluke 
87 series, for accurate measurement.

Duracell

®

 Powerpack Pro battery is almost 

fully discharged.

Press Battery Level button to verify 
battery status and recharge the 
Duracell

®

 Powerpack Pro as necessary. 

Battery Level LEDs are only accurate 
when the unit has been disconnected 
from all appliances and all charging 
sources for 15 minutes. 

Problem: Battery Status LED is red and has not changed 
to green after 24 hours of charging.

Possible Cause

Solution

The voltage at the AC wall outlet is less than 
120VAC.

Use AC wall outlet that supplies 120VAC.

Continue to charge the unit for another 
12 hours; the unit will be ready to use 
even if the Battery Status light remains 
red.

14.  Specifications

 Important notes

All specifi cations are subject to change without notice.

12V DC section

Internal battery type

Sealed/non-spillable, AGM (Ab-
sorbed Glass Mat) lead-acid

Internal battery voltage (nominal)

12V DC

Internal battery capacity (minimum)

DR300PWR ........................15Ah
DR600PWR ........................18Ah

DC power socket (maximum continu-
ous load)

20 A with automatic reset

AC power section

Output power

• Continuous output power

DR300PWR ............ 240W
DR600PWR ............ 480W

 

Output power (5 minutes)

DR300PWR ............ 300W
DR600PWR ............ 600W

• Peak AC output surge capacity

DR300PWR ............ 480W
DR600PWR ............ 750W

Output voltage

115V AC (RMS)

Output frequency

60Hz 

Output wave form

Modifi ed sine wave

No load current draw

<0.5 A DC

Input voltage range

10V to 15V DC

Low battery alarm

10.5V DC 

Low battery shutdown

10.0V DC

High battery voltage shutdown

16V DC

Over temperature shutdown

<194° F (90° C)

Overload shutdown

Yes, automatic reset

AC output short circuit protection

Yes, automatic reset

Fuse (Internal)

DR300PWR...40A x 1 (MAX), 
DR600PWR...35A x 2 (MAX)

Operating temperature range

32º–104 ºF (0º–40 ºC)

Storage temperature range

68º-122º F (-20º C - -50ºC)

Internal battery charging controller system

AC input voltage range

100-240V AC

AC input frequency

50/60Hz

Output voltage

15V DC

Rated voltage in fl oating charge

13.2Vdc@30mA

Empty load power

< 0.5W

Safety standards

ETL

Effi ciency standards

BC, CEC V

Air compressor

Pressure

160 PSI (lb/in)

Accessories

AC cord

52.4 in. (133cm)

Compressor nozzles

Red air nozzle, blue air nozzle, 
infl ator needle

Physical specifi cations

Length

15.2 in. / 38.5 cm

Width

9.3 in. / 23.7 cm

Height

10.7 in. / 27.2 cm

Weight

DR300PWR ............ 16.8 lbs. / 7.6 kg
DR300PWR ............ 20.9 lbs. / 9.5 kg

 

 

 

Summary of Contents for Powerpack Pro 1000

Page 1: ...visibility at night Comprehensive protection Reverse polarity protection The reverse polarity LED will light up when you connect the wrong terminals The reverse polarity alarm will also beep Over cur...

Page 2: ...ith the AC cord The AC cord may be permanently damaged if 12V DC appliances are operated while the AC cord is connected If you keep the Duracell Powerpack Pro in storage the battery will discharge ove...

Page 3: ...ton again when done 1 2 3 5 Using the AC outlets The Powerpack s dual USB ports can power two AC appliances at once up to a total of 240W for Powerpack Pro 1000 or 480W for Powerpack Pro 1300 For best...

Page 4: ...6 Using the 12V DC power outlet The Powerpack can operate 12V DC appliances such as those that plug into a vehicle s lighter socket that draw 20 Amps of power or less 1 Open the protective cover on t...

Page 5: ...ne purge the engine compartment and bilge of all fumes Position the Duracell Powerpack Pro on a at stable surface near the battery and away from all moving parts of the engine Ensure that the jump sta...

Page 6: ...p out of reach of children The compressor is capable of in ating to 150 PSI Do not exceed the recommended pressure of either the compressor or the object being in ated If either recommended pressure i...

Page 7: ...l 54 h battery gives approximately three times the operating time of the Powerpack s own internal 18Ah or 15Ah battery IMPORTANT BEFORE YOU START Please read these critical safety instructions careful...

Page 8: ...charging process ensuring that the battery is always fully charged but never overcharged To ensure safe recharging and maximum battery life recharge the Powerpack only with the supplied charger Batte...

Page 9: ...t then restart the Duracell Powerpack and move it to a cooler environment Problem Overload shutdown Possible Cause Solution Appliance power requirements exceed the capability of the Duracell Powerpack...

Page 10: ...is securely placed on the valve stem before closing the thumb latch The item being in ated may have a leak Make sure the item being in ated doesn t have a leak Check the compressor hose for any break...

Page 11: ...tput frequency 60Hz Output wave form Modi ed sine wave No load current draw 0 5 A DC Input voltage range 10V to 15V DC Low battery alarm 10 5V DC Low battery shutdown 10 0V DC High battery voltage shu...

Page 12: ...vide the following information Name address and telephone number Name of the DURACELL product Make and model of your device Symptoms of the problem s and what led to them Technical Support is availabl...

Page 13: ...duct as expressly stated in the limited warranty described herein the manufacturer and distributor shall not be liable for any damages whether direct indirect incidental special consequential exemplar...

Page 14: ...rademark of The Gillette Company used under license All rights reserved All logos and trademarks are used for identi cation purposes only and may be trademarks or registered trademarks of their respec...

Reviews: