![Durabrand T6609BK Service Manual Download Page 49](http://html1.mh-extra.com/html/durabrand/t6609bk/t6609bk_service-manual_2540720049.webp)
1-10-14
WF13
PIN 5
OF CN551
WF12
Q551
Collector
BT6600F01022-A
H.V./Power Supply CBA Bottom View
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.