10
You should store Tychem
®
garments in boxes, in bags or on hangers. Never step on
chemical protective garments. Never place or store heavy objects on top of chemical
garments.
Visor Antifog Procedures
Antifog treatments can be applied to the interior of Tychem
®
garment visors. Use antifog
wipes or sprays recommended by DuPont Personal Protection.
1.
Apply the antifog/anti-static cleaner to a clean, dry cloth or open the pre-packaged
antifog wipe and unfold it.
2.
Apply the antifog solution evenly to interior visor surface.
3.
Buff to a clear finish with soft cloth.
Closure Lubricants
You can lubricate a zipper or closure that is difficult to operate. You should apply
paraffin wax or YKK Zippy Cool Lubricant lightly on the outer and inner components.
After lubrication, the zipper should be closed and opened a number of times to ensure
smooth function and to remove excess lubricant.
Marking Suggestions and Restrictions
Tychem
®
garments can be marked with a permanent, felt tip marker.
Suggested Undergarments
Thick, bulky clothing worn underneath Tychem
®
garments will affect the fit of the
garment and limit the movement of the wearer. You may require a larger size Tychem
®
garment.
You will not reduce your potential for burn injury by wearing garments made of
NOMEX
®
or any other flame-resistant fabric, under Tychem
®
garments, other than
Tychem
®
ThermoPro. Tychem
®
garments, other than Tychem
®
ThermoPro, will burn
and possibly melt when exposed to a flash-fire.
Only wear non-melting materials under Tychem
®
ThermoPro garments. These could
include NOMEX
®