3. INSTALLATION OF DSF-2000

When connecting the DBM-400 Sheet by Sheet

Turn the jog dial to select “DBM400”, and press the jog dial to confirm.

Finisher Setting
DBM4OO

Perform the following settings.

q

Turn the jog dial to display “Feed Speed”, and press the jog dial to confirm.

Feed Speed
135O[mm/sec]

w

Turn the jog dial to set the value to “145”, and press the jog dial to confirm.

Feed Speed
145O[mm/sec]

e

Match the contents registered with the DBM-400 Sheet by Sheet memory number to this unit.

<DSF-2000>

<DBM-400 Sheet by Sheet>

A3

Memory number 1 : L = 420.0 mm

W = 297.0 mm

Saddle-stapling

Folding

(16.54")

(11.69")

A4

Memory number 2 : L = 297.0 mm

W = 210.0 mm

Saddle-stapling

Folding

(11.69")

(8.27")

11 

×

 17

Memory number 3 : L = 431.8 mm

W = 279.4 mm

Saddle-stapling

Folding

(17")

(11")

LTR

Memory number 4 : L = 279.4 mm

W = 215.9 mm

Saddle-stapling

Folding

(11")

(8.5")

A3SR

Memory number 5 : L = 450.0 mm

W = 320.0 mm

Saddle-stapling

Folding

(17.72")

(12.60")

Custom 1 (Initial setting: B4)

Memory number 6 : L = 364.0 mm

W = 257.0 mm

Saddle-stapling

Folding

(14.33")

(10.12")

Custom 2 (Initial setting: B4)

Memory number 7 : L = 364.0 mm

W = 257.0 mm

Saddle-stapling

Folding

(14.33")

(10.12")

Custom 3 (Initial setting: B4)

Memory number 8 : L = 364.0 mm

W = 257.0 mm

Saddle-stapling

Folding

(14.33")

(10.12")

This ends the installation procedure.

Turn off the power of this unit.

5

This ends the setting of the downstream processing unit.
This setting will be effective from the next time the power is turned on.

Summary of Contents for DSF-2000

Page 1: ...Provided By http www MyBinding com http www MyBindingBlog com Duplo DSF 2000 Sheet Feeder Installation Manual ...

Page 2: ...Specialized person only SHEET FEEDER DSF 2000 INSTALLATION MANUAL ...

Page 3: ...r future reference as it will be needed for subsequent maintenance such as relocation TO SERVICING PERSONNEL TABLE OF CONTENTS 1 Points to Note in Installation 1 1 1 Before Installing 1 1 2 Installation Location 1 1 3 Power Supply 1 2 Standard Accessories 2 3 Installation of DSF 2000 4 3 1 Preparations for DSF 2000 4 3 2 Connecting the Power Supply 5 3 3 Selecting the Downstream Processing Unit 6 ...

Page 4: ...the power supply voltage and frequency in your area match the power requirements indicated on the main name plate of the unit where the temperature range is between 5 and 35 C where the humidity range is between 20 and 85 RH no dew condensation which is not subject to direct sunlight which is subject to little or no vibration where there are no harmful chemicals which is reasonably free from dust ...

Page 5: ...nfirm that the following parts are provided 2 STANDARD ACCESSORIES SHEET FEEDER DSF 2000 INSTRUCTION MANUAL SHEET FEEDER DSF 2000 INSTALLATION MANUAL Specialized person only t q w e o 3 r u y i 2 0 1 5 6 4 ...

Page 6: ...liary paper feed plate A 1 Screw HSKW5 12 6 Screw MSKW4 8 4 Screw MSKW3 6 4 Instruction manual 1 Installation manual 1 Bridge 1 Upper bridge guide 1 Lower bridge guide 1 Front bracket 1 Rear bracket 1 Auxiliary stack guide A 1 Stack guide B 3 Power cord only 220 to 240 V AC 1 Name 2 STANDARD ACCESSORIES ...

Page 7: ...SF 2000 Auxiliary paper feed plate A Attach the front bracket rear bracket upper bridge guide and lower bridge guide to the bridge qAttach the front and rear brackets to the bridge using the screws MSKW4 8 provided 2 wAttach the upper and lower bridge guides to the front and rear brackets using the screws MSKW3 6 provided Bridge Front bracket Rear bracket Upper bridge guide Lower bridge guide ...

Page 8: ... state After installing adjust only if necessary according to the using state 5 Attach the connecting plate to the DSF 2000 as shown in the figure Use the screws HSKW5 12 provided 4 Connecting plate Attach the bridge Hook the holes on the bridge to the stepped collars on this unit and secure the bridge using the four screws HSKW5 12 provided To avoid the parts of this unit attach the bridge as sho...

Page 9: ...e clear button once Two beeps are sounded and Maintenance Menu will be displayed Press the jog dial here to enter the maintenance menu If pressed incorrectly halfway through press the escape button several times and repeat from the beginning at the initial screen 2 Maintenance Menu Select M Mode ROM Version Turn the jog dial to display Finisher Setting and press the jog dial to confirm 3 Finisher ...

Page 10: ...ory number 2 L 297 0 mm W 210 0 mm Saddle stapling Folding 11 69 8 27 11 17 Memory number 3 L 431 8 mm W 279 4 mm Saddle stapling Folding 17 11 LTR Memory number 4 L 279 4 mm W 215 9 mm Saddle stapling Folding 11 8 5 A3SR Memory number 5 L 450 0 mm W 320 0 mm Saddle stapling Folding 17 72 12 60 Custom 1 Initial setting B4 Memory number 6 L 364 0 mm W 257 0 mm Saddle stapling Folding 14 33 10 12 Cu...

Page 11: ...99T 90191 01070030M 0 ...

Reviews: