DUOVAC A10-130I User Manual Download Page 4

4 | DOC-568_EN REV04

ORIGINAL INSTRUCTIONS

2. GENERAL GUIDELINES & REFERENCE

GROUNDING REQUIREMENTS

This power unit must be grounded. If it should malfunction or breakdown, grounding provides 
a path of least resistance for electric current to reduce the risk of electric shock. This power 
unit has a power cord of 5.4’ / 1.65 m in length and is equipped with a grounding conductor 
and grounding plug. The plug must always be inserted directly into an electrical outlet that is 
properly installed and grounded in accordance with all local codes and regulations.

DO NOT USE AN EXTENSION CORD

.

WARNING:

Improper connection of the equipment grounding conductor can 

result in a risk of electric shock. Check with a qualifi ed electrician 

or service person if you are in doubt as to whether the outlet is 

properly grounded. Do not modify the plug provided with the 

power unit – if it will not fi t the outlet, have a proper outlet 

installed by a qualifi ed electrician.

The unit has a grounding attachment plug. Make sure that the 

power unit is connected to an outlet having the same confi guration 

as the plug. No adapter should be used with this power unit. The 

power unit should be connected to an independent circuit breaker.

ELECTRICAL REQUIREMENTS

The following models are to be used on a nominal circuit of 15 A at 110-120 Volts A.C. and 
60 Hz: A10-130-NA-D, A10-260I-NA-ED, SEN-260I-NA-D, STR-190I-NA, SIG-290I-NA, A50-170I-
NA, SYM-150I-NA.
The following model is to be used on a nominal circuit of 15 A at 220-240 Volts A.C. and 60 Hz: 
DIS-200-NA-D.
The following models are to be used on a nominal circuit of 10 A at 220-240 Volts A.C. and 
50 Hz: A10-260I-EU/CH/UK/SE-ED, SEN-260I-EU/CH/UK/SE-D, STR-190I-EU/CH-UK/SE-D, SYM-
270-EU/CH/UK/SE-D, SIL-280-EU/CH/UK/SE-D.
The following models are to be used on a nominal circuit of 15 A at 220-240 Volts A.C. and 
50 Hz: SIG-200-EU/CH/UK/SE-D, DIS-200-EU/CH/UK/SE-D.

NOTE

»

Other optional suffi  xes can be used, on all models, to denote 

cosmetic changes�

g

eneraL

 

guideLineS

 

tO

 

Be

 

OBSerVed

 

at

 

aLL

 

timeS

1� 

The power unit must be installed in a ventilated area away from any 

heat source;

2� 

The Duovac central vacuum system must be used only on dry 

surfaces. At no time should the system be used to draw up liquids 
nor should it be used to vacuum wet carpets or fl oors.

3� 

It is mandatory that the fi ltration cage (as applicable) be equipped 

with its permanent fi lter at all times when the system is in use;

4� 

The motor housing must never be obstructed in any way to avoid 

overheating or damaging;

5� 

DO NOT vacuum gypsum dust, fl our, mud, or any sludgy materials 

as they will cake onto the fi lter and obstruct the fi ltration system 
resulting in the overheating of the motor and thus failure of the 
power unit to function properly;

6� 

Do not attempt to shorten or modify the electrical power cord;

7� 

As a security measure, unplug the electrical power cord before 

proceeding with any maintenance;

8� 

In order for the warranty to be valid, only a Duovac authorized 

service personnel may carry out the necessary repairs or 
maintenance on the motor;

9� 

The warranty will be void if non-recommended products such as 

fi lters or any other after-sale parts as carbon brushes and motors 
are used to repair the unit. Duovac recommends strongly to use 
only Duovac certifi ed fi lters and replacement parts;

10� 

Power unit must be so positioned that the plug is always easily 

accessible.

11� 

Pertaining to a 110V/24V valve (intended for the connection of a 

current-carrying hose/motorized nozzle combination):

•  Connect only a current-carrying hose to this wall valve;
•  Do not install a wall valve outdoors;
•  Do not use with a damaged hose. Return hose to a service centre;

IMPORTANT

Duovac is not responsible for damages resulting from improper 

use. The warranty does not cover damage resulting from misuse 

or problems resulting from installation that does not conform 

to specifi cations, or any functional alterations and / or physical 

changes to the power unit. Improper or non-recommended 

installation of the system and / or power unit done against 

predefi ned principles of the user manual is also considered misuse.

All conditions and restrictions are set forth in the Duovac limited 

warranty, the user manual and the system installation guide. To 

optimize the performance and life of your Duovac power unit, it 

is important to do regular maintenance and cleaning of the fi lter 

according to the guidelines listed in this user manual.

Summary of Contents for A10-130I

Page 1: ...EN 2000868 Conforms to UL Std 1017 Certified to CAN CSA Std C22 2 No 243 M91 CAN CSA Std C22 2 No 243 10 USER MANUAL CentralVacuum System Made in Canada DOC 568 REV04...

Page 2: ...O BE OBSERVED AT ALL TIMES MODELS 5 INSTALLATION 5 POWER UNIT 5 MUFFLER 6 FLEXIBLE HOSE WITH ERGONOMIC HANDLE 6 LOW VOLTAGE WIRE CONNECTION 6 SYSTEM OPERATING INSTRUCTIONS 6 SYSTEM MAINTENANCE 7 FILTR...

Page 3: ...order to avoid a hazard The removal of the plug has to be such that an operator can check from any of the points to which he has access that the plug remains removed for commercial use models Do not...

Page 4: ...central vacuum system must be used only on dry surfaces At no time should the system be used to draw up liquids nor should it be used to vacuum wet carpets or floors 3 It is mandatory that the filtra...

Page 5: ...to be screwed to at least 2 studs Fasten the mounting bracket to the mounting board with the provided screws 3 Concrete wall Drill the holes with a concrete drill bit Insert the provided wall anchors...

Page 6: ...of the mu er is made of metal secure the mu er onto the metal elbow using the provided self tapping screw 4 OPTIONAL If you plan on exhausting the central vacuum outside install more piping starting f...

Page 7: ...replacing the filter clean the inside of the filtration cage IMPORTANT Do not turn filter inside out It must be replaced over the cage on the same fabric side as initially mounted in the factory It is...

Page 8: ...wall inlet touch the contacts which are located on the inside of the inlet with the hose wand in order to start the power unit NOTE Frame the inlet with your hands or a large enough piece of cloth su...

Page 9: ...their needs So if you have any comments or suggestions related to our products or distributors please contact us For any inquiries E mail us at info duovac com Send us your comments to NUERA AIR INC...

Page 10: ...elstellen PT Instru es Recicladoras Aparelhos usados cont m materiais valiosos que s o apro priados para reprocessamento N o colocar o aparelho no lixo dom stico normal mas sim descartar correctamente...

Reviews: