![Dungs FRM 100065 Instruction Manual Download Page 49](http://html1.mh-extra.com/html/dungs/frm-100065/frm-100065_instruction-manual_2539686049.webp)
48 …60
MC • Edition 2022.08 • No
. 278 349 R
ev
. -0
49 … 60
16. Flow volume tables
p
d
Flow volume
[
Nm
3
/h
]
p
d
-10%
p
d
+10%
max. flow volume (AC 10)
p
d
Setpoint
min. flow volume (AC 10)*
* min. flow volume = 0.1 * max. flow volume
SZ10
15.4 Storage conditions
Basically, DIN 7716 (standards for storage, maintenance
and cleaning of rubber products) applies to the storage of
diaphragms and O-Rings.
The ageing process mostly depends on
the following factors:
• Temperature
•
Thermal radiation
•
Solar radiation
•
Humidity
•
Relative humidity
•
Ozone
•
Stress conditions of the components
Proper storage
•
Storage temperature between 5° C and 20° C
•
No direct solar radiation
•
No direct heat sources in the storage area
•
No exposure to ozone
• Tension-free storage
•
Storage in polyethylene bags
•
Do not exceed the max. storage periods of 3 years