WINE CABINET INSTRUCTION MANUAL 

 

2018.V.8.  

 

 

Model:

  

 

One section model:

 

 

 

DAB-48.125B, SS 

DAU-52.146B, SS, W 

DAU-32.83B, SS, W 

 

Two section model: 

 

 

DAU-32.78DB, DSS 

DAU-46.146DB, DSS, DW 

DAB-42.117DB, DSS 

 

Three section model: 

 

DX-89.246TB, TSS

 

 

 

 

 

Summary of Contents for DAB-42.117DB

Page 1: ...NET INSTRUCTION MANUAL 2018 V 8 Model One section model DAB 48 125B SS DAU 52 146B SS W DAU 32 83B SS W Two section model DAU 32 78DB DSS DAU 46 146DB DSS DW DAB 42 117DB DSS Three section model DX 89 246TB TSS ...

Page 2: ...ed by the manufacturer or an authorized service centre or similarly qualified persons in order to avoid a hazard The use of attachments not recommended by the manufacturer may be hazardous Place the unit on a dry level surface Do not operate if the housing is removed or damaged A loose fit between the AC outlet receptacle and plug may cause overheating and a distortion of the plug Contact a qualif...

Page 3: ...g SAVE THESE INSTRUCTIONS If you are experiencing problems check the Troubleshooting Guide at the back of this manual It lists causes of minor operating problems that you can correct by yourself DISPOSAL Dispose of your appliance packaging properly Ensure that any plastic wrappings bags etc are disposed of safely and kept out of the reach of babies and young children Danger of suffocation Refriger...

Page 4: ... the cooling system caused by handling during transportation During this time we recommend that you leave the door open to clear any residual odors The door on this appliance can be opened from either the left or the right side The unit is delivered with the door opening on the left side Should you wish to open the door from the right follow the instructions Reversing the door hinge Install the ha...

Page 5: ...ICAL CONNECTION WARNING Improper use of the grounded plug can result in the risk of electrical shock If the power cord is damaged have it replaced by a qualified electrician or an authorized service center All electrical work should be carried out by a suitably qualified and competent person in accordance with local and national safety regulations Check that the voltage marked on the product corre...

Page 6: ... stopper of the bottom hinge to the opposite side Fig 3 5 Pop out the cover caps on the left side of cabinet and use them to cover the screw holes on the right hand side 6 Screw the alternative left top hinge included in the fittings on the left hand side of cabinet Fig 4 7 Unscrew and transfer the holes cover and lock catch to the opposite side of glass door Only for models with lock on the venti...

Page 7: ...ew and transfer the door adapter and to the designated opposite position of lower glass door Fig 2 3 Remove the door adapter by unscrewing the two lock screws Be careful to hold the upper glass door firmly after removing the screws And then gently pull down to remove the upper glass door from the top hinge and place it on a padded surface to avoid the risk of damage Then remove the right top hinge...

Page 8: ...ºC DOWN BUTTON Press once the DOWN button the temperature will lower 1ºC DISPLAY Display the set temperature indoor SETTING THE TEMPERATURE You can set the temperature as you desire by pushing the UP or DOWN button When you push the two buttons for the first time the LED readout will show the original temperature set at previous time The temperature that you desire to set will increase 1ºC if you ...

Page 9: ... 10 ºC Temperature setting of lower zone is same as single zone above Temperature can be adjusted from 10ºC to 18ºC USE AND CONTROL DAU 32 78DB DSS LIGHT Control the interior light ON OFF RUN Indicator light illuminates to signify the cooling mode is currently in operation POWER To control this appliance turn on off Set Upper Button To set the temperature of the upper chamber Set Lower Button To s...

Page 10: ...type of models Our appliances are in line with international standards for such appliance and in line with the latest technical developments But please remember that the noise of the compressor and the coolant circulating in the system is unavoidable DEFROSTING HYGROMETRY VENTILATION Your unit is designed with an automatic defrost system During the Off cycle the evaporator behind the rear wall of ...

Page 11: ...e door all the way opened when pulling shelves out of the rail compartment 1 Fully extend the shelf you wish to remove Fig A 2 Lift the front of the shelf up Fig A 3 Holding the shelf track push the shelf in then up to release from the rear dampers Fig B HUMIDITY CONTROL The appliance is equipped with a system for maintaining the correct level of humidity Under extremely dry environmental conditio...

Page 12: ...e you need to take the proper steps to protect your contents NOTE Irrespective of the cause if you notice either abnormal temperature or humidity levels inside your unit be reassured that only long and frequent exposure to these abnormal conditions can cause a detrimental effect on your wines VACATION TIME Short holidays Leave the unit in operation for holidays of less than three weeks Long absenc...

Page 13: ...r is open too often The door is not closed completely The door gasket does not seal properly Put the appliance in a cooler place Leave the appliance to work for a while until the set temperature has been reached Do not open the door more often than necessary Close door properly Check the door seal and clean or replace The light does not work Appliance is not connected to a power supply The circuit...

Page 14: ... from power failure 5 Faulty installation or modification made during installation 6 Damage caused by unauthorized repair 7 Any damages resulting from force majeure fire disaster or natural disaster 8 Alterations to the product without express permission from the manufacturer 9 Parts such as light removable shelves or plastic 10 Any spoilage or damage to wines or any other contents incidental or c...