Dunavox DAB-26.60B.TI Instruction Manual Download Page 5

 

plug  socket.  Any  questions  concerning  power 
and/or  earthing  should  be  directed  towards  a 
qualified  electrician  or  an  authorized  products 
service centre. 

 

  The appliance must be installed  to all  electrical, 

connections  in  accordance  with  state  and  local 
codes. 

 

 

IMPORTANT:  HIGH  HUMIDITY  CLIMATE.

 

During  periods  of  high  humidity,  some 
condensation may appear on outside surfaces of 
glass  door.  This  condensation  will  disappear 
when  humidity  levels  drop.  For  prevention,  it  is 
advisable  to  install  the  appliance  with  sufficient 
ventilation  in  a  dry  and/or  an  air-conditioned 
place. 

 
 
 
 

BUILT-UNDER INSTRUCTIONS 

Make sure  your installation does  not  block the front 
ventilation  grille.

 

The  unit  is  designed  to  fit  under 

worktops  between  820  and  890mm  in  height. 
Remove  the adjustable ventilation grille screws  and 
slide it to the required height. Tighten the screws to 
lock the grille in position. 
If the unit is fully integrated to be installed for fitting 
kitchen plinth, make sure that the ventilation gaps in 
the  plinth  are  at  least  300  square  centimeters  and 
remove  the  ventilation  grilles,  so  that  warm  air  can 
disperse unhindered. Otherwise the appliance has to 
work  harder,  resulting  in  an  increase  in  electricity 
consumption. 
 

NOTE:

 When  pushing  the  appliance  into  the  niche, 

make sure that the mains cable does not get trapped. 

 

FULLY  INTEGRATED  BUILT-IN-COLUMN 
INSTRUCTIONS 

The  unit  door  seals  the  installed  unit  almost 
completely,  so  an  air  vent  must  be  provided  in  the 
base of the housing. Warmed air must be conducted 
via  the  ventilation  shaft  to  the  rear  wall  of  the 
housing and then expelled upwards. The ventilation 
channels  should  measure  at  least  200  square 
centimeters in cross-section. 

WARNING: 

To ensure the proper functioning of the 

appliance,  air  vents  should  never  be  blocked  or 
covered. 
 

BUILT-IN CABINET INSTRUCTIONS 

Make sure your installation does not block the front 
ventilation grille.

 

And be sure the door will open and 

close properly in the chosen location. 
 

YOU CAN FIND THE DETAILED 
INSTALLATION DRAWING IN THE 
ATTACHMENT 

 

 
 
 

ELECTRICAL CONNECTION 
WARNING: 

Improper  use  of  the  grounded  plug 

can result in the risk of electrical shock. If the power 
cord  is  damaged,  have  it  replaced  by  a  qualified 
electrician or an authorized service center.

 

 
All electrical work should be carried out by a suitably 
qualified  and  competent  person  in  accordance  with 
local and national safety regulations. 
 

Check  that  the  voltage  marked  on  the  product 
corresponds with your supply voltage. 

 

Connect  this  appliance  to  a  separate,  at  least  13A 
circuit. 
 
Connection should be made via a suitable switched 
socket which is easily accessible. For extra safety it 
is advisable to install a residual current device (RCD) 
with a trip current of 30mA. 
 
Have  the  receptacle  and  the  circuit  checked  by  a 
qualified  electrician  to  ensure  that  the  socket  is 
grounded correctly. 
 

Note:  

In locations where there is frequent lightning, 

it is advisable to use surge protectors.

 

 
Do not connect the appliance to the mains electricity 
supply by an extension lead. Extension leads do not 
guarantee the required safety of the  appliance  (e.g. 
danger of overheating). 
 
The appliance must not be connected to an inverter 
and must not  be used  with a plug adapter as these 
can cause damage to the appliance’s electronic unit. 

 

The  cord  must  rest  securely  behind  the  appliance 
and not be allowed to lie or hang unprotected. 
 

WARNING: 
THIS APPLIANCE MUST BE EARTHED. 

 

 
INSTALLING THE HANDLE 
 

IMPORTANT:

  Do  not  overtighten  the  screws  &  do 

not use power tools to install the handle. Overtighten 
screw causes glass breakage. 
 

 
 
 
 
 
 
 
 
 
 
 

NOTE: The appliance must be positioned so 
that the plug is accessible.  

Summary of Contents for DAB-26.60B.TI

Page 1: ...ned approx 5 7cm by the push rod Then the door can be fully open manually NOTE Do not block the door or hold on it while it is opening If the door is blocked or held during opening the door opening mechanism and the door will be damaged The loud and repeated cracking noises will be heard Do not push the push rod in or hold on to it during closing If the push rod is blocked during closing it will n...

Page 2: ... ignition Do not operate the appliance in the presence of explosive and or flammable fumes Do not place the appliance or any of its part near an open flame cooking or other heating appliance Do not operate the appliance with a damaged cord or plug if the product malfunctions or if it is dropped or damaged in any manner If the supply cord is damaged it must be replaced by the manufacturer or an autho...

Page 3: ... result in back or other injury Never clean appliance parts with flammable fluids These fumes can create a fire hazard or explosion And do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance The fumes can create a fire hazard or explosion Do not connect or disconnect the electric plug when your hands are wet It is recommended that a separa...

Page 4: ...helves allow for maximum convenience and flexibility to accommodate various size bottles except DX 7 20 models Security lock system with keys for particular items only Passive humidity control system Humidity Box Active charcoal air filter for particular items only NOTE Features and specifications are subject to change without notice INSTALLATION BEFORE USING YOUR APPLIANCE Remove all exterior and...

Page 5: ...oper functioning of the appliance air vents should never be blocked or covered BUILT IN CABINET INSTRUCTIONS Make sure your installation does not block the front ventilation grille And be sure the door will open and close properly in the chosen location YOU CAN FIND THE DETAILED INSTALLATION DRAWING IN THE ATTACHMENT ELECTRICAL CONNECTION WARNING Improper use of the grounded plug can result in the...

Page 6: ...fter removing the screws Fig 2 3 Gently pull down to remove the glass door from the right top hinge and place it on a padded surface to avoid the risk of damage Then remove the right top hinge 9 Fig 4 4 Unscrew and transfer hinge pin 7 and or door stopper 8of the bottom hinge to the opposite side Fig 3 5 Pop out the cover caps on the left side of cabinet and use them to cover the screw holes on th...

Page 7: ...the opposite designated position or unscrew and transfer the hinge pin 7a of bottom hinge to the opposite designated position Fig 5 3 6 Unscrew and transfer the door adapter 5 and lock catch 4 to the top designated position of glass door Fig 2 7 Rotate the door 180 and relocate the glass door to the designated position Then screw the bottom hinge on the left designated position and tighten it Fig ...

Page 8: ...their internal temperature if the ambient temperature where the unit is located is lower than the set temperature USE AND CONTROL SINGLE ZONE The Controls of Your Unit POWER To turn the appliance on off press and hold the key for 5 seconds until themperature display lights up or goes out NOTE Pressing the key once can switch off the audible alarm when the alarm is on LIGHT Used to turn the inner l...

Page 9: ...perature zone and is for RIGHT temperature zone Indicator Light The indicator light is located at the right lower corner of the display The indicator light will be on when the multi key function is selected To perform the multi key function press and hold the first key then press the rest key for at least 5 seconds and then release all the keys ºF ºC Selector Select the temperature display setting...

Page 10: ... to Fahrenheit press and hold the LIGHT key for 5 seconds Setting the Temperature Control The unit has three temperature zones The temperature of all zones can be set separately The temperature settings of UPPER temperature zone are adjustable with the range 11º to 22ºC 52º 72ºF The preset temperature at the factory is 18ºC 65ºF The temperature settings of MIDDLE temperature zone are adjustable wi...

Page 11: ...WARNING Do not pull out more than one loaded shelf at a time as this may cause the unit to tilt forward Some shelves are designed to store more than 1 layer of bottles Such shelves are not allowed to slide if more than 1 layer of bottles loaded on them WARNING Do not try to slide the shelves outwards beyond the fixed position to prevent the bottles from falling WARNING To prevent damaging the door...

Page 12: ...from time to time Gurgling sound caused by the refrigerant flowing through the appliance s coils Humming noise made by the motor compressor This noise can get louder for brief periods when the motor is switching on Cracking popping sounds resulting from the materials contraction and expansion due to temperature variations Fan operating sound to circulate the air within the wine cabinet Unusual noi...

Page 13: ...tains the Owner s Manual Insert the key into the lock push in and turn it counterclockwise to unlock the door To lock the door do the reverse operation making sure metal pin is engaged completely Remove the key and place it in a secure place for safekeeping CLEANING YOUR APPLIANCE Turn off the power unplug the appliance and remove all items including shelves and rack Wash the inside surfaces with ...

Page 14: ...ill the appliance to allow air to circulate TROUBLESHOOTING GUIDE ALL MODELS PROBLEM POSSIBLE CAUSE REMEDY Appliance does not operate Appliance is not connected to a power supply The appliance is turned off The circuit breaker tripped or a blown fuse Connect the appliance Switch on the appliance Switch on circuit breaker or replace fuse Appliance is not cold enough The temperature is not set corre...

Page 15: ...the temperature that has been set This could be due to The appliance door being opened too often The ventilation opening being covered or too dusty A lengthy interruption to the power supply A large amount of bottles has been added to the unit If yes close the door Do not open the door more often than necessary Clear the obstructions and clean the dust Leave the appliance to work for a while until...

Reviews: