background image

www.dun-bri.com

+44 (0)1763 274185

[email protected]

Dun-Bri Group, Watermill Industrial Estate, Aspenden Road, Buntingford, Hertfordshire, SG9 9JS, United Kingdom

DBG M37 SERIES R65 LED 

WARNING MODULE

! WARNING ! - Do NOT look directly at the LEDs when in operation to prevent damage to your eyes.

8 STANDARD FLASH PATTERNS

01

Single Flash (ECE R65 Approved)

05

Six Flash

02

Double Flash

06

Double Flash (Fast)

03

Triple Flash

07

Quad Flash (Fast)

04

Quad Flash

08

Six Flash (Fast)

4 ADDITIONAL FLASH PATTERNS (4-LED & 6-LED VERSIONS ONLY)

09

Single Flash (Left / Right)

11

Triple Flash (Left / Right - Fast)

10

Double Flash (Left / Right)

12

Six Flash (Left / Right)

WIRING DIAGRAM

+VDC

(RED WIRE)

Ground

Battery

Fuse (Required)

Supplied with 220mm length of cable
Fuse and switches NOT supplied

Momentary Switch (Change Flash Pattern)

SYNC

YELLOW WIRE (+)

-VDC

(BLACK WIRE)

Latching Switch (On/Off)

SYNCHRONISATION INSTRUCTIONS - Ensure 
all modules are set to the same flash pattern. 
Connect yellow wires of all modules together.

TO CHANGE FLASH PATTERNS - Momentarily 
apply yellow wire to the +VDC. A simple 
momentary switch will be sufficient.

Summary of Contents for DBG M37 Series

Page 1: ...qualified automotive technician Failure to do so may void your warranty v1 1 M37 Series Voltage Range 10 30V LED Colour Amber Mounting Surface Mount 2 Screws Connection Fly Lead Flash Patterns 8 for 3 LED version 12 for 4 LED 6 LED versions Syncable Yes Dimmer Function No IP Rating IP67 MODELS AVAILABLE SKU LEDs Flash Patterns Approvals Dimensions l x h x d 308 HPF303VV 3 8 ECE R65 Class I ECE R10...

Page 2: ...ash 08 Six Flash Fast 4 ADDITIONAL FLASH PATTERNS 4 LED 6 LED VERSIONS ONLY 09 Single Flash Left Right 11 Triple Flash Left Right Fast 10 Double Flash Left Right 12 Six Flash Left Right WIRING DIAGRAM VDC RED WIRE Ground Battery Fuse Required Supplied with 220mm length of cable Fuse and switches NOT supplied Momentary Switch Change Flash Pattern SYNC YELLOW WIRE VDC BLACK WIRE Latching Switch On O...

Page 3: ... the module and all accessories before installing to ensure there are no damaged or missing parts Use foam gasket and screws provided Do NOT overtighten screws Plan all cable routing before attempting installation and ensure voltage compatibility Ensure there are no obstructions limiting visibility to traffic when mounting If the module slides or moves easily a proper installation has NOT been att...

Page 4: ...eby excluded and shall not apply to the product The buyer s sole and exclusive option in contract tort or any other practice against Dun Bri Services Ltd regarding the product and its use shall be the replacement or repair of the product as described LIMITATION OF LIABILITY In the event of liability for damages arising from this Limited Warranty or any other claim related to Dun Bri Services Ltd s...

Reviews: