DBG R65 ALUMINIUM 12-LED
DIRECTIONAL WARNING MODULE
! WARNING ! - Do NOT look directly at the LEDs when in operation to prevent damage to your eyes.
10 FLASH PATTERNS
01
Single Flash (Alternating Group 1 / 2)
06
Double Flash
02
Double Flash (Alternating Group 1 / 2)
07
Quad Flash
03
Quad Flash (Alternating Group 1 / 2)
08
Five Flash
04
Five Flash (Group 1) / Quad Flash (Group 2)
09
Quad Flash (Group 1) / Steady On (Group 2)
05
Single Flash (ECE R65 Approved)
10
Steady On
WIRING DIAGRAM
Latching Switch (On/Off)
+VDC
(RED WIRE)
Ground
Battery
ALT SYNC (GROUP 1)
GREEN WIRES (+)
Fuse (Required)
Supplied with 190mm length of cable
Fuse and switches NOT supplied
Momentary Switch (Change Flash Pattern)
(Not Connected)
ALT SYNC (GROUP 2)
GREEN WIRES (+)
SYNC
BLUE WIRE (+)
-VDC
(BLACK WIRE)
SYNCHRONISATION INSTRUCTIONS - Ensure
all modules are set to the same flash pattern.
Connect blue wires of all modules together.
ALTERNATE FLASH INSTRUCTIONS - Ensure
all modules are set to the same flash pattern.
For GROUP 1: Connect all green wires to the
+VDC.
For GROUP 2: Do not connect green wires.
Unconnected wires must be sealed to
prevent any water ingress.
TO CHANGE FLASH PATTERNS - Apply blue
wire to the +VDC between 0.5 - 2 seconds.
Applying for 2.5 seconds will revert back to
the first pattern. A simple momentary switch
will be sufficient.