www.factorybuysdirect.com
15
200245-01G
Figure 12 - Gas Connection
* Purchase the optional CSA design-certified equipment
shutoff valve from your dealer.
For propane installations, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not
reduce incoming gas pressure, heater regu-
lator damage could occur. Install external
regulator with the vent pointing down as
shown in Figure 13. Pointing the vent down
protects it from freezing rain or sleet.
For both gas types, install sediment trap in
supply line as shown in Figure 12. Place
Figure 13 - External Regulator
with Vent Pointing Down
Figure 14 - Gas Regulator Location and
Gas Line Access into Fireplace Cabinet
External
Regulator with
Vent Pointing
Down
Propane
Supply Tank
Equipment
Shutoff Valve
Ground
Joint Union
3/8" NPT
Pipe Nipple
Tee Joint
Reducer
Bushing to
1/8" NPT
1/8" NPT
Plug Tap
Test Gauge
Connection*
Sediment
Trap
Tee Joint
Pipe Nipple
Gap
3" Minimum
sediment trap where it is within reach for
cleaning. Place sediment trap where trapped
matter is not likely to freeze. A sediment trap
traps moisture and contaminants. This keeps
them from going into heater controls. If sedi-
ment trap is not installed or is installed wrong,
heater may not run properly.
Natural Gas
From Gas Meter
(5" W.C.** to
9.5" W.C.
Pressure)
Propane
From External
Regulator
(11" W.C.**
to 14" W.C.
Pressure)
INSTALLATION
Gas Regulator
Inlet Connector