VC60SDD User’s Manual
Page 16 of 18
12. Maintenance Tasks
Every morning and afternoon:
Check the temperature
Fill in the daily record sheet
On the first day of every week:
Clean the solar array
On the first day of every month:
Clean the refrigerator, condensers and compressors
Check the solar array is not shaded between 7am and 5pm
Defrost the freezer if there is a build-up of ice on the walls of the compartment
Every 6 months:
Check all mechanical fixings and electrical connections (including the array)
13. Spare parts
Listed below are the most likely spare parts required by the VC60SDD over the course of its
lifetime. It is recommended that one set of these spares is purchased for every 10 refrigerators.
Qty
Description
1
Dulas SDD controller
3
Temp probe
1
Compressor controller 101N0410
1
Compressor BD35K
1
Solar thermometer
1
Foam lid (freezer only)
1
Freezer fan
Any other parts required can be obtained by contacting Dulas on the details at the end of this
manual.