2. 

  Safety Instructions  

 

Read  the  Manual  - 

please  read  all  instructions  completely 

before  installing.  Installation  and  system  servicing  should  only  be 

carried  out  by  a  qualified  and  competent  engineer.  Work 

performed  by  persons  with  insufficient  technical  knowledge  may 

adversely  affect  the  performance  of  the  unit  or  cause  physical 

injury or damage to the equipment. 

 

The  refrigerator  is  not  to  be  used  by  persons  (including  children) 

with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of 

experience  and  knowledge,  unless  they  have  been  given 

supervision or instruction.  Children must be supervised not to play 

with the appliance. This refrigerator is for professional use only.  It 

is not designed for household use. 

 

Refrigerator and power system are heavy

 - please observe 

good  manual  handling  procedures  when  moving  the  refrigerator 

and solar power system. Only use suitable transport equipment. 

 

Live  electrical  components 

– 

The  refrigerator  operates  from 

low  voltage  DC.  There  are  high  voltage  live  circuits  within  the 

accompanying  power  supply  which  should  only  be  accessed  by 

qualified technicians.

 

 

Electrical  danger

 

–  under  fault  conditions  high  electrical 

currents  can  occur.  Never  bypass  a  circuit  breaker  and  always 

replace with the same type and rating.

 

 

DC  power  only

  -  this  refrigerator  is  designed  for  operation  with 

the supplied power system only. Do not connect the refrigerator to 

other power supplies.

 

Summary of Contents for VC225ILR

Page 1: ...DULAS VC225ILR Mains Powered Vaccine Refrigerator User Manual Ref MU VC225ILR ENG F ...

Page 2: ...STRUCTIONS 4 3 YOUR DULAS MAINS POWERED REFRIGERATOR 6 4 REFRIGERATOR COMPONENTS 7 5 MATERIAL SAFETY INFORMATION 8 6 END OF LIFE PRODUCT RECYCLING 9 7 REFRIGERATOR INSTALLATION 11 8 REFRIGERATOR LOADING 12 9 STATUS LIGHT 13 10 USER TRAINING 14 11 MAINTENANCE TASKS 15 12 VC225ILR SYSTEM LAYOUT 15 ...

Page 3: ... QUANTITY REFRIGERATOR VC225ILR Refrigerator Cabinet 1 Refrigerator Baskets 6 Refrigerator Key 2 Other Power Supply PS ILR 001 1 Screws 5x40mm for wall mount 5 Wall plugs Brown for wall mount 5 Screws 10 Wall plugs Red 10 Cable ties 10 Cable tie bases 10 MC connection tool 1 ...

Page 4: ... must be supervised not to play with the appliance This refrigerator is for professional use only It is not designed for household use Refrigerator and power system are heavy please observe good manual handling procedures when moving the refrigerator and solar power system Only use suitable transport equipment Live electrical components The refrigerator operates from low voltage DC There are high ...

Page 5: ...refrigerant Due to this fact the following information is particularly important Warning Do not damage the refrigeration circuit Ensure that sharp or pointed objects do not come into contact with the refrigeration circuit Warning Do not use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer Warning Keep ventilation openings in th...

Page 6: ...erature when the power is off the Dulas ILR has a phase change lining This lining acts as a cold store and stores energy that keeps the temperature inside the refrigerator stable when electricity is not available The temperature of the cold store in the Dulas ILR is naturally between 4 to 5 C which is the perfect temperature required for safe vaccine storage and means that the product is 100 Freez...

Page 7: ...Dulas VC225ILR User Manual Page 7 of 15 4 Refrigerator Components ...

Page 8: ...red inside the walls of the refrigerator In normal use the user will never be aware of its presence This PCM is classified under regulation EC No 1272 2008 as a category 1 aspiration hazard and is classified under regulation 67 548 EWG 1999 45 EG as having the potential to cause physical harm R65 R66 At normal ambient temperatures this product will be unlikely to present an inhalation hazard becau...

Page 9: ...igerator contain an organic phase change material that can be harmful and must be disposed of safely Please contact Dulas for advice Worn out devices must be professionally disposed of in accordance with local regulations and legislation Potentially hazardous components materials are Refrigerant gas R600a Phase change material PCM paraffins normal C5 20 Electrolytic capacitor Electronic components...

Page 10: ...nd its implementation as national law electrical equipment that has reached the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer require must be returned to our agent or find out about the approved collection and recycling facilities in your area Ignoring this European Directive may have potentially adverse effects on the env...

Page 11: ...fficient slack in the cable to allow access to the back of the refrigerator 4 Plug the Dulas PS ILR 001 into a suitable AC outlet and turn it on Then switch the DC isolator to the 1 position Within 1 minute the compressor will start if there is AC power You will be able to hear the compressor operating and feel the condensers getting warm 5 Check that the refrigerator compartment temperature displ...

Page 12: ...e vaccine compartment that drop below freezing and thus no danger of freezing vaccines Optional stacking baskets are available These are designed to make stock management easier and encourage air circulation within the compartment Try to keep the lid open for as short a time as possible Stock management Allocate a certain space for each different type of vaccine so that they may be located rapidly...

Page 13: ...wer Normal operation The refrigerator warms up slightly overnight It is usual for the compressor to start running shortly after sunrise It will run continuously for a few hours to cool the refrigerator After this time the compressor will begin cycling on and off to maintain the correct internal temperature This will continue until the sun sets at the end of the day At night there is no power to th...

Page 14: ... in accordance with the table below Total No of hours the power is off each day Running time required before full holdover is achieved at 43 C ambient Continuous operation possible once cool down has been achieved 0 2 days Y 12 4 5 days Y 16 7 days Y 20 14 days Y Before loading with vaccines ensure that the temperature display on the front of the refrigerator reads 4 5 C Daily Routine Keep the lid...

Page 15: ...s Every morning and afternoon Check the temperature Fill in the daily record sheet On the first day of every month Clean the refrigerator condensers and compressors Every 6 months Check all mechanical fixings and electrical connections 12 VC225ILR System Layout ...