background image

Service Manual for Countertop Warmer

6

SERVICE INFORMATION

Troubleshooting Procedure

SYMPTOM 

 

 

CAUSE   

 

 

 

 

 

 

 

REMEDY                                                                                  

                                                         

                                                                                                                                                                                                                           

Element Does Not Heat:   

Electrical power disconnected 

 

 

 

Plug unit into a GFI outlet                                                                                

 

 

 

      

Power source circuit breaker tripped 

      Check circuit breaker and reset

 

 

 

        Bad infinite switch 

   

 

      Check infinite switch using a multimeter

 

 

 

 

 

 

        Corroded or loose connections 

 

      Check and tighten all connections

 

 

 

        Bad or tripped hi-limit switch 

 

      Check hi-limit switch operation and continuity

Element Overheats: 

        

Bad or tripped hi-limit switch 

 

      Check hi-limit switch operation and continuity

 

 

 

        

Indicator Lamp Not On: 

        

Electrical power disconnected 

 

      Plug unit into a GFI outlet

 

 

 

        

Power source circuit breaker tripped 

      Check circuit breaker and reset

 

 

 

        Bad infinite switch 

 

 

      Check infinite switch using a multimeter

 

 

 

        Bulb burnt out   

 

 

      Replace bulb

 

 

 

 

 

 

 

        

  

 

 

 

 

https://appliancetechmanuals.com

Summary of Contents for ACTW-1

Page 1: ...gistered trademark of the Duke Manufacturing Company Duke Manufacturing Company 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg com 219556B P...

Page 2: ...IDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT PROPERLY PLACING AND SECURING ALL COVER AND ACCESS PANELS CAUTION Observe the following Provide and mai...

Page 3: ...CONNECTION 4 MAINTENANCE 4 STAINLESS STEEL CARE AND CLEANING 4 SERVICE INFORMATION 6 TROUBLESHOOTING PROCEDURES 6 PARTS REPLACEMENT 7 INFINITE SWITCH REPLACEMENT 7 GENERAL 7 INDICATOR LAMP REPLACEMEN...

Page 4: ...ECIFICATIONS OR THE SERIAL TAG DATA AND YOUR LOCAL CODE OR THE NATIONAL ELECTRICAL CODE TO BE SURE UNIT IS CONNECTED TO THE PROPER POWER SOURCE A PROTECTED CIRCUIT OF THE CORRECT VOLTAGE AND AMPERAGE...

Page 5: ...ing and cracking are early signs of stainless steelbreakdown Specialstainlesssteelcleansers can restore and preserve the protective film If signs of breakdown appear thoroughly clean and dry all surfa...

Page 6: ...eter Corroded or loose connections Check and tighten all connections Bad or tripped hi limit switch Check hi limit switch operation and continuity Element Overheats Bad or tripped hi limit switch Chec...

Page 7: ...t into a GFI outlet Figure 3 Location of Infinite Switch Bottom Removed Figure 4 Location of Indicator Lamp Button General The indicator lamp see Figure 4 is located on the control panel to the right...

Page 8: ...Plug the unit into a GFI outlet Element Replacement Figure 7 Location of Hi Limit Thermostatic Switch 6 Replace new element in the pan CAUTION Use care when handling the new element which will break v...

Page 9: ...disconnect them 4 Remove the power cord from its retaining clips 5 Removethepowercordanditsretainerring from the unit 6 Pre dress the new cord to determine amount of cord needed inside of the unit 7...

Page 10: ...Service Manual for Countertop Warmer 10 NOTES https appliancetechmanuals com...

Page 11: ...11 Service Manual for Countertop Warmer NOTES https appliancetechmanuals com...

Page 12: ...Duke Manufacturing Company 2305 N Broadway St Louis MO 63102 Phone 314 231 1130 Toll Free 1 800 735 3853 Fax 314 231 5074 www dukemfg com 219556 https appliancetechmanuals com...

Reviews: